D9000/D7000 Series Installation and Troubleshooting Quick Reference
Page 10
33317D 4/97
System Wiring Diagrams, Issue A
P
P
P
P
S
D122 DUAL
BATTERY HARNESS
ARMING STATION
TO RJ31X FOR
PRIMARY
PHONE LINE
TO RJ31X FOR
SECONDAR Y
PHONE LINE
1
6
V
A
C
4
0
V
A
6
0
H
Z
T
R
A
N
S
F
O
R
M
E
R
AS
REQ UI RED
D1255
UP TO EIGHT
SUPERVISED
D105 F EOL
DEVICE
GND
AUX
OUT
IN
D928
D105 BL
EOL DEVICE
(FOR TYPICAL BURGLAR
ALARM APPLICATIONS)
SUITABLE FOR VALVE TAMPER
AND OTHER TYPES OF
EXTINGUISHING SYSTEM
SUPER VISION.
TYPICAL INITIATING DEVICES ARE
DOOR CONTACTS NO/NC, FLOOR
MATS, MOTION SENSORS, GLASS
BREAK DETECT ORS, ETC.
DATA
AUX
GND
D8129
OCTORELAY
D8125 POPEX 1
P
P
S
S
-+
-+
D125B
110342
or
5
LO OP
A
D129
6 7 5 8 9
1
2
3
4
10
11
12 13
D129 PROVIDES OPTIONAL
WATERFLOW ALARM RETARD
FEATURE. NOT SUITABLE FOR 2-
WIRE SMOKE DETECT ORS. NOTE:
USE ZERO RETARD EXCEPT FOR
WATERFLOW.
LOOP B
D192C
P
P
S
S
+
-
ECL DEVICE 15-03130-001
LISTED
AU DIBLE
SIGNALING
DEVICES
RATED AT 10.2
TO 13.8 VDC
(DO NOT USE
VIBRATING
TYPE HORNS)
AUX P WR
ALARM TRIG
COM
SUPV
IN
ALARM CKT
P
- - +
D126
BATTERY
12V 7Ah
D126
BATTERY
12V 7Ah
CONNECT UP
TO EI GHT
OCTORELAYS
IN
OUT
AUX
GND
D8125 POPEX 2
P S
P S
-
+
-
+
DATA
AUX
GND
D8129 OCTORELAY
OR D811 ARM STATUS RELAY
CONNECT UP
TO EIGHT
OCTORELAYS
P S
P S
P
P
J3
P S
P S
P
S
P
S
= POWER LIMITED
= SUPERVISED
D1640
D8132
BATTERY
CHARGER
D126
BATTERY
12V 7Ah
D126
BATTERY
12V 7Ah
D8004 TRANSFORMER
EN CL OS URE .
REQUIRED FOR NFP A
APPLICATIONS.
OR D811 ARM STATUS R
PARALLE
PRINTER
S
S
S
S
+
P
D9210B ACCESS
CONTROL INTERFACE
5
9
10
1
4
2
Low B att er y
LEDs Of f W hen Norm al
E AR TH G RO U ND
CO MM ON
CLASS 2 T RAN SFORMER
16.5 VAC 40 VA 60 H Z
Part No. D1640
In tern all
Fused - Do Not Short
Re
u ires Unswitched Outlet
Do Not Sh are With Other E
uipment
+ AU X P OW ER
BATTERY NEG ATIVE ONLY
M aximum Char
in
Current 1.4 A mps.
PHONE MONITOR SELECT
Lo op St art
Gr ou nd Star t
TELC O
CORD
PH ONE
LE D
ON W HEN
COM M UNI C ATING
OFF WHEN IDLE
WARNING!
Mu lti-Battery Installati on Requ ires
Mo del N o. D 122 Dual Battery Harness
Improper Installa tion Can Be a Fire Hazard.
Re
uires
Re la
#D 1 36
IN J5
Battery: Replace every 3 to
5 years with M odel D126,12 V
7Amp Hr Lead Acid Battery
ON -BO ARD POI NTS
1.0K Resistor
Re
uir ed at E nd o f Li ne
Ω
VO LTAGE RA NGE S
Op en 3.7 - 5.0VDC
N orm al 2.0 - 3.0V DC
Sho rt 0.0 - 1.3V DC
PERIPHERAL DE VICE WIRING
ZONEX OUT 1
ZON EX IN 1
ZONEX OUT 2
ZON EX IN 2
ZON EX POWE R +
ZONEX COMMON
Op eration Mo nitor
Puls es W hen No rma l
Flicke rs W he n Ringing
PRO G
CONN
RE D
Y ELLOW
GREEN
BLACK
17-0582 3-002
32
POWER +
DATA BU S A
COMMON
RED
GRO UND
START
YEL
RED
Reset P in
Dis able All Exce pt B attery
C harg ing And Program min g
GRN
STE ADY OR
PU LSE
+
Ch a r
in
Status
N.F.P.A.
Style 3.5
Si
na lin
Line
Circuits
PO WER S UPPLY REQ UIREME NTS
Th e Power Sup ply P rovides a M aximum of 1. 4 Am ps For The Control and
All Accesso ry D evices F or System L oading. See Operation-Installation Ma nual
#7 4-0762 9 -000.
All External Co nnec tions Ex cep t Te rmina l (Ba ttery Po sitiv e) A re Inh ere ntly
Po wer Lim ited.
Requireme nts F or B attery S tand by T ime Ma y Reduc e All owable O utput.
CAU TIO N: See Manua l F or Power Requirem ents Relatin g to Term ina ls
R eference M anua l #74-06144 -000 For Sys tem Wiring D iagr am Issu e A
,
R eference M anua l #73-06143 -000 For Com patible Smo ke De tectors
12
15 18 21
13
11
14 16 17 19 20 22
5
6 7
P ROGRAMMABLE
ALARM OUTPUTS
Terminals
&
Req u i re s
Opti onal
D1 36 Relay
in J1 & J9
7 8
Point 1 Point 2 Point 3 Po int 4 Point 5 Point 6 Point 7 Point 8
DA TA BUS B
29
31
30
24
23
28
27
26
25
BATT ERY POS ITIV E ONL Y
+ ALTERNATE
SW I TCH ED
AUX POWER
+
3
6
7
8
This Equipment should be installed in accordance with the NFPA 7 0 (National Electric Code)
and applicable 71 Central Station, 72 Ch apter 6 Local, 72 Chapter 8 Re mote Station,
74 Household Fire (Nation al Fire protection Associatio n, Batterymarch Park, Quincy, MA 0 2269).
Printed inform ation describing proper ins tallation, ope ration, testing , maintenance, evacuation
planning and repair service is to be provided with this equipment.
D9412 Co ntrol/Communicator is UL Listed for Central Sta tion
Local
Remote Stat ion and Household
Fire Alarm
and Central S tation
Lo cal
Police Station Connect and Household Bur
lar Alarm.
D9131A PARALLEL
PRINTER
INTERFACE
UP TO EIGHT
SUPERVISED
S
S
S
S
33
R
D9412
D igita l Ala rm, Com municator Transm itte r
Up to 119 D9127 U/T PO
up to 64 D8127 U/T POPI
Up to 119 D9127 U/T POPITS, and
up to 64 D8127 U/T POPITS
Up to 14 D8128C OctoPOPITs
Up to 14 D8128C OctoPOPITs
SS
S
S
S
S
D9412 Control/Communicator