6. Sanitize the Conditioner
Mix a 3/4 cup of common (unscented) 5.25% household bleach
with 1 quart of water. Pour this solution into the brine well.
Initiate a manual regeneration. The solution will be drawn into the
conditioner during the regeneration process.
After the system has completed a manual regeneration, the condi-
tioner will be sanitized and ready for use.
14
!
Important Note: Do not pour
undiluted bleach into the water
conditioner.
Correct Stacking Using
- 50 lb Salt Blocks
Standard Block Dims
- 8.5 x 8.5 x 11.5
Total Blocks Possible
- 4 =200 lbs of Salt
Level - 4.0 level
- equal to 200 lbs (Correct)
Incorrect Stacking Using
- 50 lb Salt Blocks
Standard Block Dims
- 8.5 x 8.5 x 11.5
Total Blocks Possible
- 3 =150 lbs of Salt
Level - 4.0 level
- equal to 200 lbs (Not Correct)
IN COR RECT STACKING
CORR ECT STACKING