12. Install the Brine Overflow Line (indoors)
Run a 1/2 inch I.D.brine overflow line from the overflow elbow
on the side of the brink tank to an approved drain (see figure 8).
13. Attach the Electrical Connection
Insert the barrel plug from the DC power supply into the mating
jack in the back of the control box .
Plug the DC power supply into a 110 VAC 60 Hz or 230 VAC 50
Hz outlet.
System Start Up
1. Turn on the Water and Check for Leaks
Close all faucets and turn the water back on at the water meter or
pressure tank.
Check for leaks. If a leak is present, drain the plumbing again
before soldering.
2. Flush the Remaining Debris from the System
Open the cold water faucet on your bathtub.
Allow the system to flush the remaining dirt and debris into the
bathtub, until the water runs clear.
Open all remaining faucets and allow the plumbing to release any
trapped air in the system.
Close all of the faucets.
3 Open the Bypass Valve
Move the bypass valve handles to the service position. The valve
handles should be parallel to the pipes (see figure 9).
Open a cold water tap and allow the appliance to flush for 20
minutes or until approximately 100 gallons has passed through the
appliance.
12
Helpful Tip: It is common for
new systems to have some
color in the water. The color
should disappear after you
completely flush the system.
Helpful Tip: This procedure will
prevent dirt and debris from
entering the valve.
Figure 9