Command reference
R&S
®
ZNA
1322User Manual 1178.6462.02 ─ 20
See Chapter 4.5.6.3, "Power calibration labels", on page 195 for the possible return
values.
Suffix:
<Chn>
.
Channel number used to identify the active trace
Usage: Query only
Manual operation: See "Apply" on page 544
[SENSe<Chn>:]CORRection:SSTate?
Returns the system error correction state label of the active trace in channel <Chn>.
The response is a string variable containing the calibration state label in the trace list
('CAL', 'CAI', 'CAL OFF' ..; see Chapter 4.5.4, "Calibration labels", on page 178).
Suffix:
<Chn>
.
Channel number used to identify the active trace
Example: See [SENSe<Ch>:]CORRection:DATE?
Usage: Query only
Manual operation: See "Apply" on page 522
7.3.14.11 [SENSe:]COUPle...
The [SENSe:]COUPle... commands select the sweep mode.
[SENSe<Ch>:]COUPle <Mode>
Determines the order of partial measurements and sweeps (see Chapter 4.1.4.1, "Par-
tial measurements and driving mode", on page 88).
Suffix:
<Ch>
.
Channel number. This suffix is ignored; the sweep mode applies
to all channels in the active recall set.
Parameters:
<Mode> ALL | AUTO | NONE
AUTO – automatic mode: fast sweeps are performed in alterna-
ted driving mode, slower sweeps in chopped mode
ALL – chopped driving mode, complete all partial measurements
before proceeding to the next sweep point
NONE – alternated driving mode on, reverse the order of partial
measurements and sweeps
*RST: NONE
Example:
COUP NONE
Activate the alternated driving mode.
TRIG:LINK 'PPO'
Set the triggered measurement sequence equal to one partial
measurement. Each trigger event starts one partial measure-
ment for all sweep points.
SCPI command reference