Welcome to the R&S ZNA
R&S
®
ZNA
22User Manual 1178.6462.02 ─ 20
Distance to Fault measurements (R&S ZNA-K2): Cable type attenuations can be
defined for frequencies > 6 GHz
The integrated license server was updated to version 1.31.0.1568
Delta-L PCB characterization (R&S ZNA-K231): Configurable output directory for
deembedding files
See Chapter 5.14.11.1, "Delta-L Settings dialog", on page 699
New "Generic Device Setting for Calibration Mixer"
See "Generic Device Setting for Calibration Mixer" on page 537
Automatic level control (ALC): New 7 MHz filter in wideband signal path improves
ALC convergence speed and allows shorter pulses with ALC.
See "ALC Path IF Bandwidth" on page 481
A flatness cal performed for a frequency sweep can now be reused for power
sweeps
For better accuracy, the "Compression Point" trace statistic is now calculated using
the a-wave (instead of the stimulus axis), if possible
"Freq Step Size" setting added to all measurement setup dialogs
Solved issues
True differential mode (R&S ZNA-K61): Failed UOSM calibration of CW and power
sweeps
Mixer phase measurements (R&S ZNA-K5): Measurement results varied with
VUOSM calibration sequence
The visibility of the "Track LO" popup was not setup-specific
Pulse profile measurements (R&S ZNA-K7):
Popup hint "Measurement not fast enough. Increase bandwidth." was shown
even though the maximum bandwidth was already selected
Excessive preparation time if the number of sweep points is large
Mixer measurements (R&S ZNA-K4): Inapplicable warning "... power of Port x
should be calibrated before" during guided calibration
Noise figure measurements (R&S ZNA-K30):
The "Quickset" logic did not take the state of the internal low power spur reduc-
tion amplifier (R&S ZNAxx-B501) into account
The "Source Attenuator" field in the noise figure setup dialog displayed the
receiver attenuator value
Receiver noise figure traces could not be configured via remote control
(commands CALCulate<Ch>:PARameter:MEASure and
CALCulate<Ch>:PARameter:SDEFine dropped the R in 'NF1R' |
'NF2R' | ...)
Automatic channel calibration with the auto-detect command
[SENSe<Ch>:]CORRection:COLLect:AUTO:TYPE did not work
"Quick Setup Noise Figure" did not add the "NF21" trace to the channel
In noise figure channels, a completed flatness calibration was no longer
applied, after a reference receiver calibration was performed for a third port
What's new in firmware version 2.41