Getting Started
R&S
®
ZNA
54User Manual 1178.6462.02 ─ 20
The toolbar is divided into several icon groups, separated by vertical lines.
These icons represent the undo and redo actions that are also available
via the menu bar items "System" > "Undo" / "Redo".
Undo reverses the last action, redo reverses the last undo action (if possi-
ble).
These icons control the zoom function (Trace – [Scale] > " Zoom").
If multiple diagrams are configured, this icon toggles the "Maximize Dia-
gram" action for the active diagram (System – [Display] > "Diagram" >
"Maximize Diagram").
These icons implement the following actions, from left to right:
Add a clone of the active trace to the active diagram (single tap; same
as Trace – [Trace Config] > "Traces" > "Add Trace") or to an
arbitrary/new one (drag & drop the "Trc+" icon to the diagram area).
Add a new marker to the active diagram (single tap; similar to Trace –
[Marker] > "Markers" > "Mkr<i>") or to an arbitrary one (drag & drop
the "Mkr+" icon).
Delete the active trace (single tap the trash icon), or an arbitrary trace
(drag & drop its trace info field to the trash icon). Or delete all markers
of a trace (drag & drop the marker info field to the trash icon).
These icons provide the following actions, from left to right:
Print the current diagrams to a bitmap file (same as System –
[File Print] > "Print" > "To File...").
By default, all diagrams are printed, no matter if displayed or not.
However you can also choose to print only the active diagram (see
System – [File Print] > "Print" > "Print...").
Open the Windows® Start menu.
Open the context-sensitive help.
Restart the sweep in all channels (same as Channel – [Sweep] >
"Sweep Control" > "Restart Sweep")
These icons provide the following actions, from left to right:
Toggle advanced diagram area editing, which makes rearranging
and/or deleting diagrams a breeze.
Open the METAS Reconnection dialog
This button is only visible if, option R&S ZNA-K50 "Measurement
Uncertainty Analysis"" is installed. It is only enabled, if a METAS cali-
bration is active.
Open the configuration dialog for non-standard channel modes.
These icons provide the following actions, from left to right:
Switch on/off all sources.
Open the ALC Config dialog
This button is only visible while ALC (automatic level control) is
enabled
Open the Source Coherence dialog
This button is only visible while source coherence is enabled, which
requires option R&S ZNA-K6.
See Chapter 4.7.4, "Phase coherent source control", on page 247.
You can hide the toolbar using System – [Display] > "View Bar".