Step 7
Mount the front cover back onto the enclosure.
Step 8
Programming Options for SmartRecue
Option 1
Factory Default:
TheEmergencyPhoneswillcalldirectlyo󰀨siteandnotstopattheSmartRescue.Thatphone’sbuttonwill
light at the SmartRescue during the call.
(Keep in Default Mode if site is not manned 24/7 to answer calls onsite)
Option 2
ProgramtheSmartRescuetoAllowtheEmergencyPhonestocalltheSmartRescuerst,thenoutside
number(s):
(Used when sta󰀨 are available at certain times to answer calls)
1. Hold down Red Disconnect and Submaster 1 buttons for 5 seconds
2.Releasebuttons(youwillhearaconrmationtone)
3. Press Phone 2 button, then Red button, and then the Phone 1 button
4.PressSubmaster2button,thenSubmaster1button(youwillhearaconrmationtone)
*Note: If you need to reprogram the SmartRescue back to Default Mode see page 13.