5
CHECK VALVE
TO SPA/POOL
FILTER
CHLORINATOR
PUMP
FROM SPA/POOL
GATE VALVE
DRAIN VALVE
(CUSTOMER
INSTALLED)
BYPASS
(CUSTOMER
INSTALLED)
F10545
8. FREEZE PROTECTION
If the heater is installed in a location subject to freezing
conditions, it is important to protect the water circuit from
System Drain-Down
1. Make sure the heater is disconnected or turned off.
2. With the pool pump OFF, loosen the PVC unions
supplied with the heater on both inlet and outlet
pipes.
3. This should allow all of the water inside the heater to
drain out and prevent freeze damage to the heater.
9. ELECTRICAL
CONNECTIONS
WARNING:
and completely before installation and before use. Failure
WARNING: Risk of electrical shock. More than one
electrician in accordance with Article 680 of the National
Electrical Code, NFPA 70 and with the requirements of the
authority having jurisdiction and all applicable national,
state, provincial, and local electrical codes.
As with all electrical appli ances, under no circumstances
should you attempt to install, repair or disassemble this
directly at the fuse or breaker box.
WARNING: Serious bod ily injury or death could occur if
or breaker box.
All wiring (wire gauge) and circuit protection (breakers)
must comply with the U.S. National Electrical Code (NEC)
in the U.S.A., or the Canadian Electrical Code (CEC) in
Canada. Failure to do so could result in property damage
and/or personal injury, and void your warranty.
NOTE:
sized to a minimum of 125% of the maximum current
details).
Before installing this product, ensure that the home
maximum amperage load of the applicable model. All
t. The
is established. A separate ground conductor for each
incoming circuit is required.
CAUTION: Make sure that the electrical connections are
has been used. Make sure that the heater has been
codes.