OPERATING INSTRUCTIONS AND SHUTOFF PROCEDURES
ELECTRONIC IGNITION DIGITAL MODELS
(AUTOMATICALLY-LIGHTED PILOT)
A. This appliance is equipped with an ignition de-
vice which automatically lights the pilot. Do not
try to light the pilot by hand.
B. BEFORE OPERATING, smell all around the ap-
pliance area for gas. Be sure to smell near the
oor because some gas is heavier than air and
will settle on the oor.
WHAT TO DO IF YOU SMELL GAS:
*Do not try to light any appliance.
*Do not touch any electric switch; do not use any
phone in your building.
*Immediately call your gas supplier from a neigh-
bor’s phone. Follow the gas supplier’s instruc-
tions.
*If you cannot reach your gas supplier, call the
re department.
C. Use only your hand to push in or turn the gas
control knob. Never use tools. If the knob will
not push in or turn by hand, do not try to repair
it. Call a qualied service technician. Force or
attempted repair may result in a re or explo-
sion.
D. Do not use this appliance if any part has been
under water. Immediately call a qualied ser-
vice technician to inspect the appliance and to
replace any part of the control system and any
gas control which has been under water.
1. STOP! Read the safety information above.
2. Set the thermostat to the lowest setting.
3. Turn o󰀨 all electrical power to the appliance.
4. This appliance is equipped with an ignition device
which automatically lights the pilot. Do not try to light
the pilot by hand.
5. Remove heater door panel.
6. For Honeywell valve: Turn gas
control knob clockwise to “OFF”.
For Robertshaw valve: Models 266-406: Turn
gas control knob clockwise to “OFF”. Model
206 Push in and move gas control lever counter-
clockwise to “OFF” position.
7. Wait 5 minutes to clear out any gas. If you then smell
gas, STOP! Follow "B" in the safety information
above. If you don’t smell gas, go to the next step.
8. Turn gas control knob counter-clockwise to “ON”.
(Honeywell VR8340 and Robertshaw 7000).
9. Replace heater door panel.
10. Turn on all electrical power to the appliance.
11. Set thermostat to desired setting.
1. Set the thermostat at the lowest setting.
2. Turn o󰀨 all the electrical power to the appliance if
service is to be performed.
3. Remove heater door panel.
ROBERTSHAW 7000
GAS VALVE IID
HONEYWELL
VR8340 GAS
VALVE IID
GAS
INLET
4. For Honeywell VR8340 and Robertshaw 7000 gas
valve.
Turn gas control knob clockwise to “OFF”.
Make sure knob rests against stop.
5. Replace heater door panel.
12. If the appliance will not operate, follow the
instructions “To Turn O󰀨 Gas To Appliance”
and call your service technician or gas
supplier.
ROBERTSHAW
7200 GAS CON-
TROL LEVER
SHOWN IN "OFF"
POSITION
O
OF
GAS
INLET
FOR YOUR SAFETY READ BEFORE LIGHTING
LIGHTING INSTRUCTIONS
TO TURN OFF GAS TO APPLIANCE
PRELIMINARY
UNCONTROLLED DOCUMENT IF PRINTED

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Raypak P-R266A-ENX and is the answer not in the manual?

Raypak P-R266A-ENX Specifications

General IconGeneral
BrandRaypak
ModelP-R266A-ENX
CategoryGas Heater
LanguageEnglish

Related product manuals