EasyManua.ls Logo

Raypak raytherm p-1826 - User Manual

Raypak raytherm p-1826
36 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
INSTALLATION & OPERATING
INSTRUCTIONS
CATALOG NO. 6200.51T Effective: 05-15-18 Replaces: 07-01-16 P/N 240251 Rev. 21
WARNING: If these instructions are not followed exactly, a fire or explosion may
result causing property damage, personal injury or death.
FOR YOUR SAFETY: Do not store or use gasoline or other flammable vapors and
liquids or other combustible materials in the vicinity of this or any other appliance.
To do so may result in an explosion or fire.
WHAT TO DO IF YOU SMELL GAS:
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any phone in your building.
• Immediately call your gas supplier from a neighbor’s phone. Follow the gas
supplier’s instructions.
• If you cannot reach your gas supplier, call the fire department.
Installation and service must be performed by a qualified installer, service agency or
the gas supplier.
This manual should be maintained in legible condition and kept adjacent to the heater or in another safe place for
future reference.
Models P-926 to P-1826
& P-2100 to P-4001
Raytherm
Commercial
Swimming
Pool
Heater
®

Table of Contents

Questions and Answers

  • A
    Ann BeasleyAug 18, 2025
    What to do if my Raypak raytherm p-1826 keeps going on and off?
    • T
      Tanya HunterAug 18, 2025
      If your Raypak Swimming Pool Heater cycles on and off continuously, several factors could be responsible. Check for a dirty filter and backwash it if necessary. Ensure the water level in your pool is adequate and raise it if it's low. The external bypass setting or the pressure switch might be out of adjustment, so try adjusting them.
  • C
    Carlos BrownAug 20, 2025
    What causes a pilot outage in a Raypak raytherm p-1826?
    • M
      Mary BradshawAug 21, 2025
      A pilot outage in your Raypak Swimming Pool Heater may be due to low gas pressure, which can be resolved by adjusting the gas pressure. Another cause might be a restricted pilot, which would require cleaning the pilot. A weak pilot generator could also be the problem, in which case you should replace the pilot.
  • K
    Kathleen OrrAug 23, 2025
    How to fix a whining noise in my Raypak raytherm p-1826?
    • S
      Steven WilsonAug 23, 2025
      A whining noise, or harmonics, in your Raypak Swimming Pool Heater can stem from several causes. Check the U.G. for proper operation by placing it in hot water (110°F or higher); replace it if there's no movement. Look for and remove any debris or restrictions in the system, then flush and clean it. Also, check for debris in the gas line and remove it, or blow out the gas line. Low flow can also cause this issue, so clean the heat exchanger for scale and check the pool's pH and total alkalinity.
  • R
    Ross OwenAug 26, 2025
    Why is my Raypak raytherm p-1826 sooting?
    • J
      joshua74Aug 26, 2025
      Sooting in your Raypak Swimming Pool Heater can occur due to several reasons. High flow rates can be a cause; reduce them by adding a manual bypass valve and adjust it using a thermometer in the header drain opening to read between 105° and 110°F. An inoperative U.G. can also cause sooting; check its movement in hot water (110°F or higher) and replace if necessary. Other potential causes include air starvation (refer to installation instructions), improper venting (follow recommended installation instructions), and insects or debris clogging the burner intake ports (clean the burners).
  • L
    Lawrence ChavezAug 28, 2025
    Why does my Raypak raytherm p-1826 have a yellow lazy flame?
    • B
      Brianna SwansonAug 28, 2025
      A yellow, lazy flame in your Raypak Swimming Pool Heater can be caused by low gas pressure, which requires adjusting the gas pressure. Alternatively, insects or debris clogging the burner intake ports might be the issue, so cleaning the burners is recommended.
  • L
    linda19Aug 30, 2025
    What to do if the outer jacket of my Raypak raytherm p-1826 Swimming Pool Heater is very hot and the paint is blistered?
    • L
      lisaperryAug 30, 2025
      If the outer jacket of your Raypak Swimming Pool Heater is excessively hot and the paint is blistered, it could be due to a broken refractory caused by shipping damage or improper combustion, in which case you should replace the refractory panels. Another possible cause is excessive sooting of the heat exchanger, so determine the cause of the sooting and correct it.
  • M
    Marc TorresSep 1, 2025
    How to prevent liming or scale forming on the heat exchanger of my Raypak raytherm p-1826 Swimming Pool Heater?
    • K
      Kelly HardySep 1, 2025
      To prevent liming or scale formation on the heat exchanger of your Raypak Swimming Pool Heater, ensure your pool water's pH is between 7.3 and 7.8, with a total alkalinity of 100-150 PPM maximum, and a hardness of 150-400 PPM maximum.
  • W
    william83Sep 3, 2025
    What to do if the filter is not running long enough on my Raypak raytherm p-1826?
    • M
      manncorySep 3, 2025
      If the filter on your Raypak Swimming Pool Heater isn't running long enough, try resetting the time clock. It could also be due to a dirty filter, so cleaning the filter is recommended. Additionally, an undersized gas line or meter could be the issue; refer to the installation instructions for guidance.
  • B
    Brian Ingram DVMSep 6, 2025
    Why is the gasket on my Raypak raytherm p-1826 brittle and leaking?
    • C
      Cory MartinSep 6, 2025
      If the gasket on your Raypak Swimming Pool Heater is brittle and leaking due to overheating, it might be because the heater is running after the pump shuts off. Refer to the section on pressure switch adjustment for guidance.
  • P
    Peter BennettSep 8, 2025
    What causes my Raypak raytherm p-1826 to bypass too much water?
    • R
      Richard SimmonsSep 8, 2025
      Inspect the bypass for movement; if there is no movement, replace it.

Raypak raytherm p-1826 Specifications

General IconGeneral
Voltage120V
IgnitionElectronic
CategorySwimming Pool Heater
Fuel TypeNatural Gas
Warranty1 year on parts

Related product manuals