EasyManua.ls Logo

Rcom MAX 50 - Abnormal Temperature Alarm; Egg Turning ON;OFF Control; Egg Turning Melody

Rcom MAX 50
24 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
How to Set Abnormal High or Low Temperatue Alarm
How to Set Egg Turning ON/OFF
In a state of button being pressed, press
button then the setting will be changed as required.
What is Abnormal High or Low Temperature Alarm?
It is alarm soulds when incubator temperature is higer or lower than setting value because of various reasons
such as room temperature change or disorder of temperature controlling system.
Egg Turning Test : If you press button for
about 5 seconds, egg turning test will be effected once.
(Keep pressing the button)
Once (Lamp ON)
Egg turning Interval
: 2 hours
4Times (Lamp ON)
Egg turning Interval :
an hour
2Times (Lamp ON)
Egg turning Interval
: 3 hours
3Times (Lamp OFF)
Egg turning Interval
: OFF
repeat
* Max. abnormal temp. alarm limit (0.0 ~ 5.0 Default Setting:2.0)
* Min. abnormal temp. alarm limit (0.0 ~ -5.0 Default Setting:-3.0)
How to Set
5Sec.
Set required
high range with
UP / DOWN button
Set required
low range with
UP / DOWN button
Save setting and
pass to current
temp. & humi.
indication
Save setting and
pass to
low humi. set
3. Function Settings
Be sure to set TURNING OFF 3 days before hatching.
Plese press button over 5 seconds
to turn ON or OFF egg turning melody.
Egg Turning Melody ON / OFF
(3) Temperature & Humidity Setting /
How to Set Egg-Turning
DIGITAL INCUBATOR
13

Related product manuals