DCN: 141-02071-01 Page 9
your controller’s user manual for details on removing a device from a Z-Wave
network.
Exclusion: Removing the TBZ48 from a Network
:
1. Set your primary controller to Remove mode, to remove the TBZ48 as a node
on your network (see your controller’s user manual for detailed instructions).
2. Press the FAN button and hold until the screen changes to the SETUP
screen.
3. Press the UP button until the ZWAVE is shown on the status line, press
Select.
4. REMOVE should be displayed, press Select. The status line will show the
progress as the TBZ48 has been removed from a network. Wait until SUCCESS
or FAILED is shown on the status line.
5. The controller will indicate the TBZ48 has been removed from the network.
The radio icon will disappear from the screen.
Setback Mode Operation
If your controller does not support full thermostat device class functions, it may still be able
to control the energy saving AWAY mode of the thermostat through BASIC_SET
commands.
Sending the BASIC_SET (Value = 0x00), the thermostat will go into the AWAY mode and
use the predefined AWAY setback setpoints. These setpoints are set in the Main Menu
Away Setpoints item.
Sending the BASIC_SET (Value = 0xFF), the thermostat will revert back to the Home
mode it was in before the BASIC_SET (Value = 0x00) command was sent.
Note that when the BASIC_SET commands are sent, the TZ45 will momentarily display the
new mode.