DCN: 140-02121-02 Page 1
Installation Guide
Model TBZ48A
Battery Powered Z-Wave Thermostat
This thermostat is compatible with most HVAC systems, including the following:
24VAC systems Note: requires both the R and C wires unless battery powered.
Standard gas/oil/electric heating systems
o 1 stage heating and cooling
o 2 stage heating and cooling
Heat Pump systems:
o 1 stage heating and cooling
o 2 stage heating and cooling
o 2
nd
or 3
rd
stage Auxiliary heating (heat strips)
Do NOT use for line voltage controls (120/240VAC)
Replacing an existing Thermostat
Stop! Before disconnecting wires from the existing thermostat, label
the wires with the terminal markings from the old thermostat and record
them below. Take a picture…it will be very helpful with troubleshooting or
if you need to reinstall the old unit.
Read all instructions before starting installation.
Standard HVAC System Wiring
Record the old thermostat wire
connections and terminal
marking here
Heat Pump HVAC System Wiring
Record the old thermostat wire
connections and terminal
marking here
* if you have a terminal marked “B” with a brown wire attached to it, that means you have a
changeover (CO) with heating type heat pump system. Be sure to set the change over
type in the SYSTEM menu to CO type: H (heat). Otherwise leave it set to C (cool).