Door control
FireProV2
Manual
Please keep this manual with attachments carefully!
26
After setting the end positions, the control can be configured via the menu as desired. An
important parameter to configure is the door mode (0.1). Leave this parameter to 1 for hold to run
operation or set it to 2 for pulse operated opening and closing hold to run or opening and closing at
3 for Pulse operated.
Display flashes Display Display flashes Display
The position of the door is indicated by the symbols shown on the display.
DISPLAY :
Move open End position Move close End position Random Pre-end
Open Close Position Position
10.3 Automatic or hold to run operation
The door runs in hold to run open and close when the controller is set to factory settings.
If desired, the door can be opened automatically by setting parameter 0.1 to 2 in the menu.
Automatically open and close can be set by setting parameter 0.1 to 3.
10.4 Duration NES Motor
Make sure that the duration of a motor with cam/mechanical limit switches, parameter 2.1, is not
set too short. Set it longer than the time the door needs to move from completely close to
completely open position. When the duration is to short, the door will be stopped and the Stop
button must be pressed first before a new command can be given to give the door a new open or
close command.