Term Meaning
Parameterisation mode State of the RM-310 C / RM-310 CT in which the operator can parametrise
the device (the RM-310 C / RM-310 CT is at the parameter selection or pa-
rameter setting level).
Pulse time Duration of a control pulse of the valve outputs
R-IMC-BUS Data bus system of RECO with special BUS protocol
(RECO Inter Module Communication Protocol)
Sensor alarm Alarm triggered when a faulty sensor signal is present.
Service alarm Alarm triggered when the operating hours (parameter C2) set for the service
interval have been reached.
Service operating hours
counter
Depending on the mode set (parameter C1) the internal service operating
hours counter is activated. The service alarm is triggered when the set
operating hours (parameter C2) have been reached.
Solenoid valve (also pilot valve) electromagnetically operated valve for the pneumatic
selection of the diaphragm valves of the filter. The diaphragm valves, in
turn, release the compressed air pulses for filter cleaning.

Related product manuals