What to do if Record 102-020.110.805 displays 'STG defective'?
- MmillerbrookeAug 31, 2025
If the Record Door Opening System displays 'STG defective', reset the system. If the issue persists, replace the control unit.
What to do if Record 102-020.110.805 displays 'STG defective'?
If the Record Door Opening System displays 'STG defective', reset the system. If the issue persists, replace the control unit.
What to do if Record Door Opening System displays 'RED VRR test'?
If the Record Door Opening System displays 'RED VRR test', check the setting of the locking device.
What to do if Record 102-020.110.805 displays 'Error ELS1'?
If the Record Door Opening System displays 'Error ELS1', calibrate ELS with 2 light pulses.
What does 'T. motor high' mean on Record Door Opening System?
The 'T. motor high' message on your Record Door Opening System is a warning that extends hold-open times. The door might work sluggishly. Check for any mechanical hindrances.
Why Record 102-020.110.805 displays 'Motor 1 overheat'?
The 'Motor 1 overheat' message on your Record Door Opening System indicates that motor 1 is too warm, and the door may work sluggishly.
What to do if Record 102-020.110.805 Door Opening System displays 'Interrupt. mot. 1'?
If the Record Door Opening System displays 'Interrupt. mot. 1', it means the motor is not plugged in or is faulty. Reset the system after checking the motor.
What to do if Record 102-020.110.805 Door Opening System shows 'VAK closed automatic'?
If the Record Door Opening System displays 'VAK closed automatic', change the operating mode on BDE-D to Locked and then back to Automatic. Actuate manual unlocking or completely reset it, and adjust the locking device, as the locking is set on "wrong" position.
Why Record Door Opening System shows 'Low BAT voltage'?
The 'Low BAT voltage' message on your Record Door Opening System indicates that the battery is missing or not plugged in. The door will still function if mains voltage is supplied.
What to do if Record 102-020.110.805 Door Opening System displays 'VAK defective'?
If the Record Door Opening System displays 'VAK defective', it means the locking device is hampered. Check if the VRR cable is connected and adjust the door leaves and locking device.
What to do if Record Door Opening System displays 'Encoder fault'?
If the Record Door Opening System displays 'Encoder fault', reset the system. This may resolve the issue if the encoder or cable is faulty or not properly connected.
Brand | Record |
---|---|
Model | 102-020.110.805 |
Category | Door Opening System |
Language | English |
Describes the purpose and scope of the maintenance and troubleshooting instructions for the record system 20.
Explains key terms and symbols used in the document for clarity and readability.
Specifies the intended application of the record system 20 and the operator's responsibility.
Outlines general safety rules and accident prevention measures for operating the sliding door system.
Lists necessary special tools, aids, and documents for efficient maintenance.
Details regular maintenance tasks including cleaning, mechanical checks, and functional controls.
Covers administrative tasks like informing the operator and signing service reports.
Explains the purpose and format of the logbook for recording maintenance and interventions.
Explains how to read operator system information, software versions, and phone numbers from the BDE-D display.
Details how the BDE-D displays errors and how to interpret them for troubleshooting.
Lists and explains common error messages, abbreviations, and symbols for troubleshooting.
Explains 4-digit error codes for additional units on the CAN bus and their troubleshooting.
Describes the procedure for disconnecting the record system 20 from power and battery.
Provides guidance on sorting and disposing of machine parts according to regulations.