AKKU PASS
FLASH PASS
EEPROM PASS
RTC PASS
CAN PASS
FPC902
Version 2
1
7
.
1
Aug
3
20
13
14:32 : 06
Service STG >
FPC902
Service STG Slave >
Flash-Programmer >
Setup >
Connect with STG ...
Yes
Accept all parameter
from the STG?
Offline
Parameter download
from STG ...
Continue
STA20_UL V1.00
Break-out USA
Automatic
0 Errorless
SERVICE STG
Parameter >
Maintenance >
Functions >
Operation mode >
Connect the FPC-902 to the black 4 conductor plug located on the left side
of the Series 5100 control. The following sequence of screens should occur.
Servicing the Series 5100(Sys.20) with the FPC-902 Hand Terminal
Jan 2014 BG
Press “OK”
Press “OK”
Press “OK”
The screen sequences on the following pages start from this point and document the various
adjustable parameters in the control. When at any of the screens shown below, the above
screen can be accessed by pressing the “ESC” key one or more times.
Configure System
Learning System >
Service Sensor >
Question and Answer IconNeed help?

Do you have a question about the Record 5100 Series and is the answer not in the manual?

Record 5100 Series Specifications

General IconGeneral
BrandRecord
Model5100 Series
CategoryDoor Opening System
LanguageEnglish

Summary

Initial Setup and Connection

FPC-902 Terminal Connection

Connects the FPC-902 Hand Terminal to the Series 5100 control unit.

Initial Screen Sequence

Presents the initial sequence of screens displayed on the FPC-902 during servicing.

Core System Configuration

Door Type, Motor, and Lock Settings

Configures door type, motor selection, and lock type for system operation.

Battery and System Parameters

Sets battery type and related system operational parameters.

Driving Cycle - Speed and Force

Speed and Movement Control

Adjusts door speeds, acceleration, deceleration, and creep section for movement control.

Force and Ramp Settings

Configures holding force and ramp profiles for smooth door operation.

Driving Cycle - Time Delays and Seal

Time Delays and SSK Settings

Manages time delays for door opening, remote signals, and SSK functions.

Seal and Reset Parameters

Configures door seal behavior and system reset functions.

Driving Cycle - Opening and Motor

Opening Limits and Obstruction Sensitivity

Sets partial opening limits and obstruction sensitivity for door operation.

Motor Type and Dual Motor Configuration

Identifies motor type and configures dual motor operation.

Entrance System and Battery Operation

Entrance System Measurement Settings

Configures door opening width and height measurements for the entrance system.

Battery Operation and Power Failure Response

Manages battery operation modes and emergency response during power failures.

Door Type and Control Panel

Door Type and Interlock Configuration

Selects door type and configures interlock system behavior.

Mechanical Panel Integration

Sets up parameters for connected mechanical control panels.

Display Panel Configuration

Language and Contrast Settings

Configures display language and contrast levels for display modules.

Keyboard Mode and Brightness

Sets keyboard mode and brightness levels for the display panel.

Display Brightness and Operation Modes

Brightness Adjustments

Adjusts brightness levels for display modules and TD Backlite.

Default Operational Mode

Determines the default operating mode for the system.

Locking Mechanism Configuration

Locking Function and Type Selection

Configures locking functions and selects the lock type.

Start Delay and Error Checking

Manages start delay after unlocking and error checking for locking mechanisms.

Input/Output and Communication Settings

CAN-BUS Module Management

Automatically identifies and displays connected CAN-BUS modules.

Input/Output Terminal Configuration

Configures specific input/output terminals and their associated functions.

Safety and Emergency Input/Output

Emergency Stop and Functionality

Manages emergency stop reset and related input/output functions.

SIO/SIS Signal Configuration

Configures SIO/SIS signals for door position and safety.

Miscellaneous System Functions

SIA and TOWA Functionality

Configures SIA for safety signals and TOWA for partial opening.

Push-to-Actuate and Holding Force

Sets up push-to-actuate features and holding force for door operation.

Time Safety and Alarm Settings

Lead Time Configuration

Configures lead time parameters for door opening and closing sequences.

Time Safety and Alarm Display

Configures time safety for inputs and alarm display settings.

Maintenance and Parameter Resets

Maintenance Reset Procedures

Details procedures for resetting maintenance counters and programs.

Factory and Default Settings Reset

Resets system parameters to factory or default settings.

Function Testing and System Calibration

Release AKI and ELS Testing

Tests actuation from interior sensors and acquires safety beam characteristics.

Learning Parameter and System Reset

Configures learning parameters and performs system resets.

Diagnostics and Operational Status

Operation Mode Status Display

Displays the current operational mode of the door system.

Diagnostic Information and Error Logging

Accesses diagnostic data, error history, and parameter status.

Software Update Procedures

Flash Programmer Setup

Guides the user through setting up the flash programmer for software updates.

Software Verification Process

Verifies software versions for updates and checks stored software on the SD card.

License and Language Management

License Renewal Procedure

Details the process for renewing system licenses.

Language Selection for Terminal

Enables selection of the display language for the terminal.

Related product manuals