3
CAUTION
AN INADEQUATELY INSTALLED AND ADJUSTED DOOR COULD CAUSE DAMAGE TO THE EQUIPMENT AND MAY CAUSE
INJURY TO OTHERS.
HAVE YOUR DOOR PERIODICALLY INSPECTED & SERVICED AT LEAST TWICE PER
YEAR BY AN ADSA (Automatic Door Suppliers Association) CERTIFIED TECHNICIAN.
THIS DOOR IS NOT INTENDED TO BE DISCONNECTED FROM THE MAINS AT NIGHT!
Introduction
This manual contains all the information you may require to install, maintain and service your Battery backup
system.
The System allows a DFA 127 Swing Door Operator to be used even during mains power fail situations.
Safety
Your door system has been manufactured to the latest applicable safety standards; in order for you to comply you will
need to have the door installed to any relevant safety standards by a qualified engineer.
Any “Danger Areas” of the door set must be indentified and protected. Examples of protection are safety sensor and
barriers to prevent persons /objects entering these areas.
The manufacturer recommends that the door complies with the BS EN 16005 as a minimum but, may need to comply
with other standards such as: Part M, Building Regulations, The Machine Directive and / or Disability Discrimination Act.
Please consult the relevant professional bodies for details.
Environmental Requirements
The DFA Battery Backup contains electronics and batteries that may have materials that could be hazardous to the
environment. Please remove these products and dispose of them safely, in accordance with the laws of your country,
when the operator is decommissioned.
Intended Use
Internal use only Not to be installed externally
Only for use with the record DFA 127 Swing Door Operator