Counter 2 Operating Mode (Batch Model only)
-21-
The chart below shows operating modes for Counter 2 of the Batch Counter
Model.

RESET TYPE RESET OUTPUT 3
Auto
To
Zero
To
Preset 3
Latched Timed
1
2
3
4
5
6
7
8
MODE
#
Manual
At Timed
03 End
COUNTER 2 OPERATING MODES (C48CB ONLY)
Auto Reset to Preset 3 at 03 Timed Output End-8
Auto Reset to Preset 3, 03 Timed-7
Auto Reset to Zero at 03 Timed Output End-6
Auto Reset to Zero, 03 Timed-5
Manual Reset to Preset 3, 03 Timed-4
Manual Reset to Preset 3, 03 Latched
-3
Manual Reset to Zero, 03 Timed-2
Manual Reset to Zero, 03 Latched-1
Reset Type:
Auto - unit automatically resets when count reaches
Output 3 or timed output 3 end.
Manual - Counter can only be manually reset by a User
Input or by Serial Communications command.
Reset to:
Zero - When reset (manually or automatically), counter 2 goes to zero.
Output 3 is triggered when counter 2 value reaches Preset 3 Value
Preset - When reset (manually or automatically), the Preset 3 Value is loaded
into Counter 2. Output 3 is triggered when Counter 2 reaches zero.
At Timed Output 3 End:
When this mode is selected, Auto Reset occurs when the Output 3 time
value elapses and Output 3 deactivates. If not selected, Auto reset occurs
when output 3 is triggered.
Output 3:
Latched - When Output 3 activates, it stays activated or latched until it is
manually reset.
Timed - When Output 3 is activated, it stays activated for the time specified
by the Output 3 Time Value. Output 3 deactivates after the Output 3 time
duration expires.