EasyManua.ls Logo

red lion RL25U - User Manual

red lion RL25U
12 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
RL25U Multi-Purpose Pump
English
EN
OWNER'S MANUAL
This submersible multi-purpose pump is designed for clear water transfer applications and household water
removal. The pump is for use with water only.
Do NOT use this pump for:
Transferring potable water
Effluent or sewage applications
Applications where debris (gravel, sand, etc.), abrasives, or corrosives are present
As a pond pump, or for pumping seawater
Sprinkler systems—this pump does not deliver enough pressure for sprinkler applications
Locations classified as hazardous according to the National Electrical
Code (ANSI/NFPA)
The pump motor is equipped with an automatic resetting thermal protector, and may restart
unexpectedly. Thermal Protector tripping is an indication of motor overloading or overheating. This
can be caused by application issues such as an obstructed pump impeller, pump running dry, pump
air-locked, pump short cycling, excessively high or low voltage supply, or possibly a pump, motor,
bearing, or seal that has reached the end of its useful life.
Please examine your pump carefully to ensure that no damage occurred during shipment. If dam-
age has occurred, please contact the place of purchase. They will assist you in replacement or
repair, if required.
This product is covered by a Limited Warranty for a period of 60 months from the date of original purchase by
the consumer. For complete warranty information, refer to www.redlionproducts.com
; or, call Technical Support
for a printed copy.
Specifications
Model Phase Volts Hz Amps Breaker Size Watts HP Shut Off
RL25U 1 115 60 2.5 10 A 230 1/4 19 ft (5.8 m)
BEFORE GETTING STARTED
This equipment should be installed and serviced by technically
qualified personnel who are familiar with the correct selection
and use of appropriate tools, equipment, and procedures. Failure
to comply with national and local electrical and plumbing codes
and within Red Lion recommendations may result in electrical
shock or fire hazard, unsatisfactory performance, or equipment
failure.
Know the product’s application, limitations, and potential haz-
ards. Read and follow instructions carefully to avoid injury and
property damage. Do not disassemble or repair unit unless
described in this manual.
Refer to product data plate(s) for additional precautions, operat-
ing instructions and specifications.
Failure to follow installation or operation procedures and all
applicable codes may result in the following hazards:
Risk of death, personal injury, or
property damage due to explosion, fire,
or electric shock.
Do not use to pump flammable or explosive fluids such as gaso-
line, fuel oil, kerosene, etc.
Do not use in explosive atmospheres or hazardous locations as
classified by the NEC, ANSI/NFPA70.
Do not handle a pump or pump motor with wet hands or when
standing on a wet or damp surface, or in water until the unit is
unplugged or electrically disconnected.
When a pump is in its application, do not touch the motor, pipes,
or water until the unit is unplugged or electrically disconnected.
If the power disconnect is out of sight, lock it in the open posi-
tion and tag it to prevent unexpected application of power.

Questions and Answers

  • A
    Allison StevensJul 29, 2025
    Why red lion RL25U runs but does not discharge fluid?
    • M
      Mary WagnerJul 29, 2025
      If your Red Lion Water Pump runs but doesn't discharge fluid, the impeller might be blocked or jammed, so you should clean it. Alternatively, the pump height to the water source might be too high; reduce it. Also, the inlet to the impeller might be plugged, requiring you to pull and clean the pump.
  • B
    barbaramooreAug 7, 2025
    How to fix Red Lion Water Pump that does not deliver rated capacity?
    • C
      Charles LeonAug 7, 2025
      If your Red Lion Water Pump isn't delivering its rated capacity, first check if the pump height is too high for the pump's capability. Also, a partially blocked inlet can be the cause, so clean the inlet. Moreover, the impeller or discharge pipe might be clogged; pull the pump and clean it, and check the hose for kinks or blockages. Finally, impeller wear due to abrasives can reduce capacity, requiring pump replacement.
  • J
    Justin ValdezAug 18, 2025
    What to do if my Red Lion Water Pump does not turn on?
    • A
      Ashley BrewerAug 18, 2025
      If your Red Lion Water Pump doesn't turn on, there are several possible causes. First, ensure the pump is plugged into a working GFCI circuit. If it is, check the circuit breaker or fuse and turn it on or replace it if necessary. Corroded power cord plug prongs can also prevent the pump from turning on, so clean the prongs. If the pump has an overload, allow it to cool and investigate the cause, such as a jammed impeller. In some cases, the motor may be inactive, requiring pump replacement.

Summary

Specifications

Before Getting Started

Danger Warnings

Installation

Physical Installation

Steps for physically setting up the pump and hose connections.

General Safety Warnings

Operation

Maintenance

Periodic Service

Steps and recommendations for regular pump cleaning and upkeep.

Maintenance Safety

Troubleshooting

Replacement Parts and Accessories

red lion RL25U Specifications

General IconGeneral
ModelRL25U
Outlet Size1 in
Housing MaterialCast Iron
Seal TypeMechanical
Horsepower1/4 HP
Voltage115V
Phase1 Phase