DISTANCE (metres) The air inlet must be at a distance of:
1.5 m UNDER Windows, doors, smoke outlets, cavities, ....
1.5 m HORIZONTALLY Windows, doors, smoke outlets, cavities, ....
0.3 m ABOVE Windows, doors, smoke outlets, cavities, ....
1.5 m AWAY from smoke outlet
Since the Erica stove is sealed, and should you wish for the whole installation to be sealed as well, follow the instructions below:
• the air required for combustion must be directly taken from outside
• use a pipe having Ø 60 mm minimum and maximum length 2 metres; see stove rear for the connection.
• If installed in double wall ue (PGI system) the combustion air is taken from the hollow space. For proper operation the pipe must
be 2m long at most.
• In the installation stage it is required to check the minimum distances required for the combustion air intake because, by way of
example, an open window or door cause a vortex that might subtract the combustion air required for the stove.
• On the outer wall it is required to install a 90° elbow to protect the combustion air ow from the eects of wind: aim the elbow
opening down.
• Fit the elbow with a bird protection grate so that it is not obstructed by any object.
• Warnings: check with the local regulations whether there are any restrictive regulations concerning the combustion air intake: if so,
they must be applied. In some installation conditions the sealed connection is compulsory, in case of doubt always adhere with the
most restrictive regulations.
• Connection procedure of sealed chamber stove with PGI pipes:
• Original pipe position all retracted (STAGE 1)
• Extract the pipe by about 2 cm (STAGE 2)
• Insert the female pipe Ø6 cm (STAGE 3)
STEP 1
STEP 2
STEP 3