AC Voltage/Current
Datalogger
Instruction
Manual
R5003
REED Instruments
1-877-849-2127 | info@reedinstruments.com | www.reedinstruments.com
Question and Answer IconNeed help?

Do you have a question about the Reed Instruments R5003 and is the answer not in the manual?

Summary

Product Quality

Safety

Features

Included

Specifications

Instrument Description

LCD Description

Details the indicators and segments of the datalogger's Liquid Crystal Display (LCD) screen.

Meter Description

Supplemental Display Notes

Software Installation

Software Operation

Operating Instructions

Power ON;OFF

Instructions for turning the REED R5003 AC Voltage/Current Datalogger on and off.

Setup Mode

Steps for connecting the datalogger to a PC, installing software, and configuring a new session.

MAX;MIN

Procedure to display the Maximum and Minimum AC current or Voltage values recorded.

Auto Power Off

Battery Replacement

Accessories and Replacement Parts

Product Care

Product Warranty

Product Disposal and Recycling

Product Support

Overview

The REED R5003 is an AC Voltage/Current Datalogger designed for comprehensive monitoring and recording of electrical parameters. This instrument offers dual-channel measurement capabilities, allowing it to simultaneously record two voltage or current measurements, or one of each. Its primary function is to log AC voltage and current data over extended periods, providing valuable insights for electrical diagnostics, energy management, and system performance analysis.

Function Description:

The R5003 datalogger is engineered to capture and store up to 256,000 AC voltage and current measurements. It features a dual input system, enabling the monitoring of two distinct electrical signals concurrently. The device's LCD provides real-time display of time/date, current readings, and maximum/minimum values, offering immediate feedback to the user. A key feature is its user-adjustable sample rate, which can be set from 1 second up to 24 hours, allowing for flexible data collection tailored to specific application needs. High and low alarms can be configured to alert users when measurements fall outside predefined thresholds.

Data collected by the R5003 can be downloaded to a computer via a USB interface, where it can be analyzed using the included software. This software facilitates detailed examination of the logged data, trend analysis, and report generation. The instrument is designed for practical use, featuring a magnetic back that allows it to be securely attached to various metallic surfaces, ensuring stability during data collection. Additionally, it incorporates a low battery indicator and an auto shut-off function to conserve battery life.

The datalogger operates through a straightforward interface. To begin a new recording session, the R5003 is connected to a PC via USB, and the included software is used to configure the logging parameters. Once configured, the device can be disconnected from the PC and deployed. Measurements are initiated by pressing and holding the START/STOP button, indicated by a "REC" icon on the display. The device can be set for continuous recording, where newer data overwrites older data once the memory is full, or it can stop recording when memory is exhausted. After data collection, the R5003 is reconnected to the PC to download and analyze the stored information. The MAX/MIN button allows users to quickly review the highest and lowest AC current or voltage values recorded during a measurement session directly on the device's display.

Important Technical Specifications:

  • AC Voltage Range: 10 to 600V
  • AC Voltage Accuracy: ±(2.0% rdg + 1V)
  • AC Voltage Resolution: 0.1V
  • AC Current Range: 10 to 200A
  • AC Current Accuracy: ±(2.0% rdg + 1A)
  • AC Current Resolution: 0.1A
  • Channels: Dual channel, TRMS AC Voltage or Current
  • Display: Dual LCD
  • Min/Max Function: Yes
  • Datalogging Capabilities: Yes
  • Real-Time Clock and Date Stamp: Yes
  • Selectable Sampling Rate: 1 second to 24 hours
  • Max Datapoints: 256,000
  • Auto Shut-off: Yes (after 5 minutes of inactivity, not applicable during datalogging)
  • Low Battery Indicator: Yes
  • Clamp Jaw Opening: 0.5" (12.7mm)
  • Power Supply: 4 AAA Batteries or AC Adapter
  • Battery Life: Sampling Time Dependent
  • Overvoltage Category: CAT. III 600V
  • Product Certifications: CE
  • Operating Temperature: 0 to 122°F (0 to 50°C)
  • Storage Temperature: -4 to 140°F (-20 to 60°C)
  • Operating Humidity Range: 10 to 75%
  • Dimensions: 4.5 x 2.5 x 1.3" (114 x 63 x 34mm)
  • Weight: 8.7oz (248g)

Usage Features:

The R5003 is designed for ease of use and versatility in various applications.

  • Dual Input Measurement: Allows for simultaneous monitoring of two AC voltage or current sources, or one of each, providing comprehensive data for complex systems.
  • Adjustable Sample Rate: Users can set the data logging interval from 1 second to 24 hours, optimizing data resolution for short-term events or long-term trends.
  • High and Low Alarms: Configurable alarms provide immediate notification if measured values exceed or fall below specified limits, crucial for proactive monitoring.
  • Magnetic Back: The integrated magnetic back enables convenient and secure mounting of the instrument and its sensors to metal surfaces, freeing up hands and ensuring stable measurements.
  • LCD Display: The clear LCD simultaneously shows time/date, current readings, and Max/Min values, offering a quick overview of the measurement status.
  • USB Interface and Software: Data can be easily downloaded to a PC for in-depth analysis, trending, and reporting using the included software, enhancing diagnostic capabilities.
  • Included Accessories: The package comes with 2 AC Current Clamp Sensors, 2 Voltage Sensors, 4 Large Alligator Clips, 4 Basic Test Probes, a USB Cable, Software, an AC Adapter, and Batteries, providing a complete solution for immediate use.
  • "LO" and "CH" Indicators: The display provides clear indicators for open circuits ("-LO-") and unconnected sensors ("-CH-"), aiding in troubleshooting and ensuring proper setup.
  • MAX/MIN Functionality: A dedicated button allows for quick review of the maximum and minimum values recorded during a measurement session directly on the device.

Maintenance Features:

Proper maintenance ensures the longevity and reliability of the REED R5003 datalogger.

  • Battery Replacement: When the low battery indicator appears, the 4 x AAA batteries can be easily replaced by removing a screw on the back of the meter and opening the battery cover.
  • Auto Power Off: The meter automatically turns off after 5 minutes of inactivity (unless datalogging) to conserve battery life.
  • Storage Recommendations: For long-term storage, it is recommended to remove the AAA batteries to prevent leakage and potential damage to the instrument.
  • Cleaning: The product and its accessories should be cleaned with a biodegradable cleaner. It is important not to spray the cleaner directly on the instrument but to apply it to external parts only.
  • Environmental Care: Avoid placing the instrument in high vibrating areas, direct sunlight, high temperatures, or high moisture environments to prevent damage.
  • Safety Guidelines: Users are advised not to attempt to repair or modify the instrument themselves. Servicing should only be performed by an authorized service center to maintain warranty validity and ensure proper functioning. The battery cover should never be opened during measurements, and the meter should be disconnected and switched off before replacing batteries.
  • Product Warranty: REED Instruments provides a one-year warranty against defects in material or workmanship, ensuring support and repair or replacement services if issues arise under normal use.
  • Disposal and Recycling: The product contains electronic components and must be disposed of separately from standard waste products, following local laws and regulations for environmental responsibility.

Reed Instruments R5003 Specifications

General IconGeneral
BrandReed Instruments
ModelR5003
CategoryData Loggers
LanguageEnglish

Related product manuals