FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC Canada, V4G 1H4
919-961g
Panorama
®
P33CE Zero Clearance
Direct Vent Gas Fireplace
Owners &
Installation Manual
www.regency-re.com
MODEL: P33CE-NG11 Natural Gas
P33CE-LP11 Propane
Panorama P33CE
- Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other
appliance.
- WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch: do not use any phone in your building.
Leave the building immediately.
Immediately call your gas supplier from a neighbour's phone. Follow the gas supplier's
instructions.
• If you cannot reach your gas supplier, call the fire department.
- Installation and service must be performed by a qualified installer, service agency or the gas supplier.
Warning
FIre or explosion Hazard
failure to follow safety warnings exactly could result in serious
injury, death, or property damage.
02.14.22
Installer: Please complete the details on the back cover
and leave this manual with the homeowner.
Homeowner: Please keep these instructions for future reference.
Certified to/Certifié pour: CSA 2.17-2017
ANSI Z21.88-2017
CSA 2.33-2017
Tested by:
French Manual: https://bit.ly/3l8nBhl
Manuel en français : https://bit.ly/3l8nBhl

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Regency Panorama P33CE-NG11 and is the answer not in the manual?

Overview

This document is the Owners & Installation Manual for the Regency Panorama® P33CE Zero Clearance Direct Vent Gas Fireplace, available in Natural Gas (P33CE-NG11) and Propane (P33CE-LP11) models. It provides comprehensive instructions for safe installation, operation, and maintenance of the appliance.

Function Description

The Regency Panorama® P33CE is a state-of-the-art direct vent gas fireplace designed to provide warmth and ambiance similar to a wood fireplace. It utilizes "balanced flue" co-axial technology, where the inner liner vents combustion products outside, and the outer liner draws outside combustion air into the chamber, eliminating the need for heated room air for combustion. This design ensures efficient operation and prevents warm room air from escaping up the chimney. The appliance is approved for alcove and mobile/manufactured home installations (after first sale), where not prohibited by local codes.

Important Technical Specifications

  • Models: P33CE-NG11 (Natural Gas), P33CE-LP11 (Propane)
  • Certifications: CSA 2.17-2017, ANSI Z21.88-2017, CSA 2.33-2017, and GAS-FIRED APPLIANCES FOR USE AT HIGH ALTITUDES CAN/CGA-2.17-2017.
  • Gas Type: Only the type indicated on the rating plate. Not convertible without a certified kit.
  • Electrical Supply: 115VAC, 1.13A, 60Hz.
  • Gas Connection: Right-hand side of the appliance.
  • Electrical Connection: Left-hand side of the appliance. A metal receptacle box is supplied/installed for 120-volt electrical connections.
  • Vent System: "Balanced flue" co-axial system. Approved vent systems include Regency® Direct Vent Flex System, Simpson Dura-Vent Pro, Selkirk Direct-Temp, Amerivent Direct Vent, Metal-Fab Sure Seal, Security Secure Vent, and ICC Excel Direct.
  • Maximum Vertical Venting: 40 ft (12.2m) straight vertical with rigid pipe vent systems for Propane and Natural Gas.
  • Minimum Vertical Venting: 8'6" (2.6m) for rigid pipe systems.
  • Horizontal Venting: Maximum 10 ft (3m) centerline to centerline for rigid pipe systems.
  • Clearances to Combustibles:
    • Front Floor Clearance: 0"
    • Sidewall (on one side): 9" (229mm) from side opening of unit
    • Ceiling (room and/or alcove): 30" (762mm) from top opening of unit
    • Alcove Width: Min. 84" (1219mm) sidewall to sidewall
    • Alcove Depth: Max. 36" (914mm) front to back wall
    • Mantel: 12" (305mm) from top opening of unit
    • Mantel Clearances: 15-3/4" (400mm) from top opening of unit (minimum)
    • Horizontal Flue Clearances: Top 2-1/2", Side 1-1/2", Bottom 1-1/2"
    • Vertical Flue Clearances: Flex Vent 1-1/2", Rigid 1-1/4"
  • Natural Gas (P33CE-NG11):
    • Burner Inlet Orifice Sizes: #44
    • Max. Input Rating: 20,000 Btu/h
    • Min. Input Rating: 14,000 Btu/h
    • Supply Pressure: min. 5.0" w.c.
    • Manifold Pressure (High): 3.5" w.c. (0.87kPa)
    • Manifold Pressure (Low): 1.6" w.c. (0.39kPa)
    • Minimum Air Shutter Opening: 3/16"
  • Propane (P33CE-LP11):
    • Burner Inlet Orifice Sizes: #55
    • Max. Input Rating: 19,500 Btu/h
    • Min. Input Rating: 15,500 Btu/h
    • Supply Pressure: min. 11.0" w.c.
    • Manifold Pressure (High): 10" w.c. (2.49kPa)
    • Manifold Pressure (Low): 6.4" w.c. (1.59kPa)
    • Minimum Air Shutter Opening: 3/8"
  • Altitude: Approved for altitudes up to 4500 ft (1372 m).

Usage Features

  • Proflame I Remote Control System: Allows control of main burner on/off, flame modulation (6 levels), thermostat and smart thermostat functions, accent light modulation (6 levels), and comfort fan speed modulation (6 levels).
  • On Demand Pilot Light (Seven Day Safety Timer): In Continuous Pilot (CPI) mode, the pilot light will shut down after seven consecutive days of inactivity. It can be relit by cycling the remote control's on/off button. This feature does not apply in Intermittent Pilot (IPI) mode.
  • CPI/IPI Switch: Allows switching between Continuous Pilot (CPI) and Intermittent Pilot (IPI) modes. CPI keeps the pilot lit continuously, aiding start-up in cold weather and reducing glass condensation. IPI saves fuel by only lighting the pilot when there is a call for heat.
  • Key Lock Function: Locks remote control keys to prevent unsupervised operation.
  • Optional Wall Thermostat: Can be installed for room temperature control. When active, the remote receiver is set to ON, disabling remote control features.
  • Optional Fan: A 120V AC fan can be installed to circulate heated air. Speed is adjustable via the remote control.
  • Optional Enamel/Brick Panels: Decorative panels for the firebox interior.
  • Optional 4-Sided Faceplate: Decorative trim for the fireplace opening.

Maintenance Features

  • Annual Inspection: The appliance and venting system should be inspected annually by a qualified service person to ensure proper operation and clear combustion/ventilation air flow.
  • Cleaning:
    • Burner and control compartment should be cleaned at least annually by brushing and vacuuming.
    • Logs are fragile and should be handled with care, cleaned with a soft, clean paintbrush.
    • Appliance and glass door should be cleaned with a damp cloth (never when hot). Abrasive cleaners should not be used. Glass should be cleaned with a gas fireplace glass cleaner when cloudy.
    • Enamel panels should be cleaned with an ammonia-based cleaner to remove fingerprints before heating to prevent burn stains.
    • Fan area should be vacuumed regularly to prevent dust build-up on fan blades and housing.
  • Pilot Flame Check: Periodically check for two strong blue flames, one around the flame sensor and one across the burner.
  • Burner Check: Periodically check burner for proper position, condition, and flame appearance (steady, not lifting or floating).
  • Gas Leak Tests: Regular checks of all gas line connections with a soap and water solution or gas leak detector.
  • Log Replacement: If logs are broken, they must be replaced with proper replacement logs and positioned as shown in the manual to prevent carbon build-up and altered performance.
  • Glass Gasket Replacement: Use a tadpole glass gasket (Part # 936-155) for the Flush Front.
  • Flue Extension Kit: Available for vertical flex pipe extensions (Part #946-756).
  • Firestop/Firestop Spacer: (Part #946-757) must be installed when passing through floor or ceiling levels.

Regency Panorama P33CE-NG11 Specifications

General IconGeneral
BrandRegency
ModelPanorama P33CE-NG11
CategoryIndoor Fireplace
LanguageEnglish

Related product manuals