15
Control of the functions
Information
How to remove the santoprene tube:
Important, for the after-sales service of a device with a pH pump, it is essential
to remove the santoprene tube to avoid spraying acid into the box during
transport.
- Remove the glass
- Pull the left soproprene tube to release it
Pulling the tube will turn the pump manually.
- Remove the santoprene tube.
To replace / change:
- Place the left part of the tube.
- Turn the pump by engaging the tube in its housing.
- Replace the pump glass.
Message
and
check up
Reading error / regulation
HS Probe, empty canister.
The display flashes: Indicates that the probe is at the
limit of operation or calibration. So change the probe.
dEF flashes: when the pH or redox in the pool does
not reach the injection setpoint.
Check:
- the can is empty
- the measurement is too far from the instruction
- Adjustment of the pool volume
To delete dEF:
- After changing the bottle or checking the
probe.
- Open the door of the and and then press the adjusting
bolt until the measurement reappears.
The display or dEF flashes