air temperature from +5 to +40 ˚С;
relative air humidity from 35 % to 85 % at
the temperature of 25 ˚C;
atmospheric pressure from 630 to 800 mm Hg.
1.2.4 According to EIC, the device should not be
used in re risk and explosive conditions.
1.2.5 The main technical specications of the
device are given in Table 1.
Table 1
Parameters and Specications Value
IR light source peak wavelength (for
Regula 7027F.100 and 7027F.110), nm
1)
870±20
UV light source peak wavelength (for
Regula 7027F.110), nm
1)
365±2
Color of the visible light sources
1)
white
Field of view (horizontal x vertical), mm 128×87
Frame size, dots(pixels)
1)
2592×1944 (5 Mp)
Connection interface USB 2.0
Power supply voltage (via the USB port
of the PC), V
5±0,2
Rated current consumption, A, max 0,9
Device weight, kg, max 0,8
Device dimensions, mm, max 148×208×95
RFID Frequency band, kHz 13 553–13 567
Max power < 60 dΒuΑ/m@10mt
1) — Light source and camera parameters correspond