REPLACEMENT & OPTIONS
#EA30N Nylonbrush
#EA30B Brassbrush
#EA30SS Stainlesssteelbrush(notsuppliedwithsteamcleaner)
#EA60N 60mmnylonbrush
#EADRAIN Draincleaner
#EAEXT Extension
#EABNOZZLE Bentnozzle
#EAWALL Wallpaperremover
#EACLOTH2 Replacementcloths(2/pack)
#JTPOWDER Cleaningpowder
Otheraccessoriesareavailablebycontactingyourretailerorvisiting
www.reliablecorporation.com.
TROUBLESHOOTING
Donotoperatethesteamcleanerwithadamagedcord,plugorifthesteamcleaner
hasbeendroppedordamaged.Toavoidriskofelectricshock,donotdisassemble
or attempt to repair the unit on your own. Return the unit to Reliable Corporation
(seewarranty)forexamination,repairorreplacement.
10
PROBLEM
No steam is released through
the steam fittings.
Dropsofwaterleakfromthe
attachments.
Dirtywateriscomingout.
Not enough steam pressure.
Pump is not stopping.
REMEDY
1. Turnsteamunitontothe
2nd position.
2. Put required amount of
waterintotank.
3. Plug unit into outlet.
4. Waitforlight(3)toturnon.
1. Waitforlight(3)toturnon.
2. Letwaterrunthroughsys-
tem until steam comes out.
1. Followcleaninginstructions
inbook.
1. Turnthedialuntilthedesired
pressure is reached.
1. Press the switch on the
steam handle. Hold for a
few seconds until the pump
is primed.
POSSIBLE CAUSES
1. Steam unit is not turned on.
2. Watertankisempty.
3. Unitisnotpluggedin.
4. Generator is not fully
heated.
1. Unitisnotfullyheated.
2. Condensation was created
from non-use.
1. Scale may have built up.
1. Thedialonthehandlemay
be set too low.
1.Anair(bubble)maybein
the pump.