The Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523
Model F1FR Series
Quick Response
Standard Spray
Bulletin 014 Rev. L
Bulletin 014 Rev. L
Model F1FR56 Sprinkler Types
Standard Upright
Standard Pendent
Conventional
Vertical Sidewall
Horizontal Sidewall
Model F1FR56 Recessed Sprinkler Types
Standard Pendent/F1/F2/FP
Horizontal Sidewall
Model F1FR56 Concealed Sprinkler Types
Standard Pendent
Model F1FR42, F1FRXLH & F1FR28 Sprinkler
Types
Standard Upright
Standard Pendent
Model F1FR42, F1FRXLH & F1FR28 Recessed
Sprinkler Types
Standard Pendent
Model F1FR56LL & F1FR42LL Low Lead Sprinkler
Types*
Standard Pendent
Less than 0.25% Lead Content
Listing & Approvals
1. Underwriters Laboratories Inc. and Certified for
Canada (cULus).
2. Factory Mutual Approvals (FM)
3. Loss Prevention Council (LPCB, UK)
4. VdS Schadenverhütung GmbH
5. *NSF Certified to NSF/ANSi Standard 61 Annex G
6. EC Certificate: 0786-CPD-40239 (RA1414), 0786-
CPD-40251 (RA1425), 0786-CPD-40252 (RA1475)
UL Listing Category
Sprinklers, Automatic & Open (VNIV)
Quick Response Sprinkler
Product Description
Reliable Models F1FR56, F1FR56LL, F1FR42, F1FR42LL,
F1FRXLH & F1FR28 Series Sprinklers are quick response
sprinklers which combine the durability of a standard sprin-
kler with the attractive low profile of a decorative sprinkler.
The Models F1FR56, F1FR56LL, F1FR42, F1FR42LL,
F1FRXLH & F1FR28 Series Recessed automatic sprinklers
utilize a 3.0 mm frangible glass bulb. These sprinklers have
demonstrated response times in laboratory tests which are
five to ten times faster than standard response sprinklers.
This quick response enables the Model F1FR56, F1FR56LL,
Pendent Conventional
Recessed
Pendent/F1/F2
Upright
Vertical Sidewall Horizontal Sidewall
Recessed
Horizontal Sidewall
Recessed
Pendent/FP
Concealed
Pendent
XLH Upright XLH Pendent
XLH Recessed
Pendent F1/F2
XLH Recessed
Pendent FP
F1FR42, F1FR42LL, F1FRXLH &
F1FR28 Series sprinklers to apply wa-
ter to a fire much faster than standard
sprinklers of the same temperature rat-
ing.
The glass bulb consists of an accu-
rately controlled amount of special fluid
hermetically sealed inside a precisely
manufactured glass capsule. This glass bulb is specially
constructed to provide fast thermal response.
At normal temperatures, the glass bulb contains the fluid
in both the liquid and vapor phases. The vapor phase can
be seen as a small bubble. As heat is applied, the liquid
expands, forcing the bubble smaller and smaller as the liq-
uid pressure increases. Continued heating forces the liquid
to push out against the bulb, causing the glass to shatter,
opening the waterway and allowing the deflector to distrib-
ute the discharging water.

Other manuals for Reliable F1FR Series

Question and Answer IconNeed help?

Do you have a question about the Reliable F1FR Series and is the answer not in the manual?

Summary

Model F1 FR Series Quick Response Standard Spray

Sprinkler Types and Configurations

Details various sprinkler models including Upright, Pendent, Recessed, and Concealed types.

Listing and Approvals

Lists certifications and approvals from UL, FM, LPCB, VdS, and EC.

Product Description and Operation

Explains the quick response mechanism and features of the F1FR series sprinklers.

Application and Technical Specifications

Technical Data and Material Composition

Provides detailed technical data, including K-Factor, pressure, and material composition.

Sprinkler Installation Data

F1 FR56, Upright, Pendent & Conventional Sprinklers Installation Data

Provides installation data for F1FR56 upright, pendent, and conventional sprinklers.

Installation Aids and Procedures

Summary

Model F1 FR Series Quick Response Standard Spray

Sprinkler Types and Configurations

Details various sprinkler models including Upright, Pendent, Recessed, and Concealed types.

Listing and Approvals

Lists certifications and approvals from UL, FM, LPCB, VdS, and EC.

Product Description and Operation

Explains the quick response mechanism and features of the F1FR series sprinklers.

Application and Technical Specifications

Technical Data and Material Composition

Provides detailed technical data, including K-Factor, pressure, and material composition.

Sprinkler Installation Data

F1 FR56, Upright, Pendent & Conventional Sprinklers Installation Data

Provides installation data for F1FR56 upright, pendent, and conventional sprinklers.

Installation Aids and Procedures

Overview

The Reliable F1FR Series sprinklers are quick-response fire protection devices designed for use in fixed fire protection systems, including wet, dry, deluge, or preaction systems. These sprinklers combine the durability of a standard sprinkler with the aesthetic appeal of a low-profile decorative sprinkler. They are available in various configurations, including standard upright, standard pendent, conventional, vertical sidewall, horizontal sidewall, recessed pendent, recessed horizontal sidewall, and concealed pendent types. Low-lead versions (F1FR56LL and F1FR42LL) are also available, containing less than 0.25% lead content and NSF Certified to NSF/ANSI Standard 61 Annex G.

Function Description:

The F1FR Series sprinklers operate on a frangible glass bulb principle. The glass bulb contains a precisely controlled amount of special fluid, hermetically sealed within a glass capsule, designed for fast thermal response. At normal temperatures, the fluid exists in both liquid and vapor phases, with the vapor visible as a small bubble. When exposed to heat from a fire, the liquid expands, compressing the vapor bubble. As heating continues, the internal pressure forces the liquid to push against the bulb, eventually causing the glass to shatter. This opens the waterway, allowing water to discharge through the sprinkler and be distributed by the deflector to suppress the fire. These quick-response sprinklers have demonstrated response times in laboratory tests that are five to to ten times faster than standard response sprinklers, enabling them to apply water to a fire much more rapidly.

Important Technical Specifications:

  • Discharge Coefficients (K-Factor):
    • F1FR56, F1FR56LL: K 5.6 (US) / 80 (Metric)
    • F1FR42, F1FR42LL, F1FRXLH: K 4.2 (US) / 60 (Metric)
    • F1FR28: K 2.8 (US) / 40 (Metric)
  • Thread Size: 1/2" NPT (R1/2) for all models.
  • Maximum Working Pressure: 175 PSI (12 bar).
  • Minimum Working Pressure: 7 PSI.
  • Temperature Ratings: Available in various ratings with corresponding bulb colors:
    • Ordinary (57°C/135°F): Orange bulb
    • Ordinary (68°C/155°F): Red bulb
    • Intermediate (79°C/175°F): Yellow bulb
    • Intermediate (93°C/200°F): Green bulb (Low Lead Sprinklers available only with 200°F/93°C rating)
    • High (141°C/286°F): Blue bulb (Not available for recessed sprinklers)
  • Sprinkler Height: 2.25" (57mm) for most pendent and upright models; 2.63" (67mm) for horizontal sidewall models.
  • Materials:
    • Frame: DZR Brass, QM Brass, or Low Lead Brass.
    • Deflector: CDA Alloy 260, CDA Alloy 220, or CDA Alloy510.
    • Load Screw: CDA Alloy 360 or CDA Alloy 544.
    • Pintle: CDA Alloy 360 or CDA Alloy 544 (XLH Only).
    • Cup: CDA Alloy 651 or CDA Alloy 693.
    • Washer: Nickel Alloy 440 or Alloy 360 coated with PTFE Adhesive Tape.
    • Bulb: Glass.
  • Listings & Approvals: Underwriters Laboratories Inc. (ULus), Factory Mutual Approvals (FM), Loss Prevention Council (LPCB, UK), VdS Schadenverhütung GmbH, NSF Certified (for low lead models), and EC Certificate.
  • UL Listing Category: Sprinklers, Automatic & Open (VNIV), Quick Response Sprinkler.

Usage Features:

  • Installation: Quick response sprinklers are intended for installation as specified in NFPA 13. It is crucial not to intermix quick response and standard response sprinklers within the same system. Care must be taken to ensure the orifice size, temperature rating, deflector style, and sprinkler type comply with the latest published standards and local authority having jurisdiction.
    • Wrenches: Model D Sprinkler Wrench is used for standard upright, pendent, conventional, and vertical sidewall sprinklers. Model GFR2 Sprinkler Wrench is used for recessed pendent and horizontal sidewall sprinklers. Model RC1 Sprinkler Wrench is used for concealed pendent sprinklers. Using any other type of wrench may damage the sprinklers.
    • Torque: A leak-tight ½” NPT (R1/2) sprinkler joint can be achieved with a torque of 8-18 ft-lbs (10.8 - 24.4 N-m). Over-tightening beyond the maximum recommended torque can cause leakage or impairment.
    • Recessed Sprinklers: For recessed models, specific escutcheons (F1 or F2) are required. The escutcheon data table provides information on approvals and dimensions.
    • Concealed Sprinklers: Concealed models (F1FR56/CCP & F1FR56LL/CCP) utilize a threaded Model CCP cup factory-attached to the sprinkler and a push-on cover plate assembly. These sprinklers should not be installed in ceilings with positive pressure in the space above. After cutting a 2 5/8" (67mm) diameter hole in the ceiling, the sprinkler is installed with the Model RC1 Wrench. A Teflon®-based thread sealant should be applied to the sprinkler threads only. The cover plate is pushed onto the cup, and final adjustment is made by hand turning the cover plate until the skirt flange makes full contact with the ceiling. Cover plate removal requires turning in the counter-clockwise direction.
  • Corrosion Resistance: Many models are available with corrosion-resistant finishes, including polyester coated (cULus listed, FM approved, LPCB & VdS approved) and Electroless Nickel PTFE (Teflon®) plated (cULus listed).
  • Bulb Protectors: Glass bulb sprinklers are shipped with orange bulb protectors to minimize damage during shipping and handling. These protectors MUST be removed at the time the sprinkler system is placed in service for fire protection. Removal should be done by hand, undoing the clasp; tools should not be used to remove the protectors.

Maintenance Features:

  • Inspection and Maintenance: F1FR Series sprinklers and the sprinkler system should be inspected and maintained in accordance with NFPA 25.
  • Cleaning: Sprinklers should NOT be cleaned with soap and water, ammonia, or any other cleaning fluids. Dust should be removed using a soft brush or gentle vacuuming.
  • Damage/Paint: Any sprinkler that has been painted (other than factory-applied) or damaged in any way must be removed and replaced.
  • Spare Sprinklers: A stock of spare sprinklers should be maintained to allow for quick replacement of damaged or operated sprinklers.
  • Storage: Prior to installation, sprinklers should be maintained in their original cartons and packaging to minimize the potential for damage that could cause improper operation or non-operation.

Reliable F1FR Series Specifications