Features
cULus Listed Residential Sprinklers
Available in pendent and horizontal sidewall orientations
Decorative finishes available, including recessed
escutcheons and conical concealed cover plates
Product Description
Model F1Res Series sprinklers are residential sprinklers with a
3 mm glass bulb operating element. A variety of K-Factors as
well as recessed and conical concealed options are available
as detailed in this Bulletin.
The F1Res Series sprinklers are specially engineered for fast
thermal response to meet the requirements of UL 1626. They
are intended for installation in accordance with NFPA 13, 13R,
and 13D.
Application
The Model F1Res Series sprinklers cULus Listed Residential
sprinklers are intended for use in accordance with NFPA
13, NFPA 13R, or NFPA 13D. The Model F1Res residential
sprinklers are cULus Listed for use in residential occupancies
and residential portions of any occupancy, where permitted
by NFPA 13, NFPA 13R, or NFPA 13D. For NFPA 13R and
NFPA 13D applications, the design flow and pressure shall
not be less than the minimum flow and pressure specified
www.reliablesprinkler.com
Residential Sprinkler Summary
Sprinkler
Model
Sprinkler
Identification
Number (SIN)
Orientation
K-Factor
gpm/psi
1/2
(lpm/bar
1/2
)
Thread Size
NPT or ISO7-1
Installation Options
Max. Coverage Area
ft x ft (m x m)
F1Res30 R3511 Pendent 3.0 (43) 1/2 Pendent or Recessed 16 x16 (4.9 x 4.9)
F1Res49 R3516 Pendent 4.9 (71) 1/2 Pendent or Recessed 20 x 20 (6.1 x 6.1)
F1Res58 R3513 Pendent 5.8 (84) 1/2 Pendent or Recessed 20 x 20 (6.1 x 6.1)
F1Res76 R7618 Pendent 7.6 (109) 3/4 Pendent or Recessed 20 x 20 (6.1 x 6.1)
F1Res30 CCP R3511 Pendent 3.0 (43) 1/2
Conical Concealed or
Recessed
14 x 14 (4.3 x 4.3)
F1Res49 CCP R3516 Pendent 4.9 (71) 1/2
Conical Concealed or
Recessed
20 x 20 (6.1 x 6.1)
F1Res58 CCP R3513 Pendent 5.8 (84) 1/2
Conical Concealed or
Recessed
20 x 20 (6.1 x 6.1)
F1Res76 CCP R7618 Pendent 7.6 (109) 3/4
Conical Concealed or
Recessed
20 x 20 (6.1 x 6.1)
F1Res44 HSW R3531 Horizontal Sidewall 4.4 (63) 1/2 Recessed 16 x 20 (4.9 x 6.1)
F1Res44 SWC R3531 Horizontal Sidewall 4.4 (63) 1/2 Conical Concealed 16 x 20 (4.9 x 6.1)
F1Res58 HSW R3533 Horizontal Sidewall 5.8 (84) 1/2 Recessed 16 x 20 (4.9 x 6.1)
F1Res 58
HSWX
RA3533 Horizontal Sidewall 5.8 (84) 1/2 Recessed 14 x 26 (4.3 x 7.9)
Table A
in the Listed Design Criteria tables in this Bulletin. For NFPA
13 applications, the design density shall be a minimum
of 0.1 gpm/sf (4.1 mm/min), but in no case shall the flow
and pressure be less than the minimum flow and pressure
specified in the Listed Design Criteria tables in this bulletin.
Model F1Res Series sprinklers are listed for use in wet
systems only.
cULus Listed
Model F1Res Series Glass Bulb
Residential Sprinklers
Bulletin 135 February 2020
Question and Answer IconNeed help?

Do you have a question about the Reliable F1Res Series and is the answer not in the manual?

Summary

Reliable F1 Res Sprinkler Features

cULus Listed Residential Sprinklers

Identifies sprinklers as cULus Listed for residential use.

Pendent and Horizontal Sidewall Orientations

Details available sprinkler orientations for different installations.

Reliable F1 Res30 Residential Pendent Sprinkler

Technical Specifications and Materials

Details technical specs, materials, finishes, and temperature ratings.

Installation Dimensions and Components

Illustrates components and provides installation dimensions for the sprinkler.

Hydraulic Design Criteria

Lists flow, pressure, and coverage data for hydraulic calculations.

Reliable F1 Res49 Residential Pendent Sprinkler

Technical Specifications and Materials

Details technical specs, materials, finishes, and temperature ratings.

Installation Dimensions and Components

Illustrates components and provides installation dimensions for the sprinkler.

Hydraulic Design Criteria

Lists flow, pressure, and coverage data for hydraulic calculations.

Reliable F1 Res58 Residential Pendent Sprinkler

Technical Specifications and Materials

Details technical specs, materials, finishes, and temperature ratings.

Installation Dimensions and Components

Illustrates components and provides installation dimensions for the sprinkler.

Hydraulic Design Criteria

Lists flow, pressure, and coverage data for hydraulic calculations.

Reliable F1 Res76 Residential Pendent Sprinkler

Technical Specifications and Materials

Details technical specs, materials, finishes, and temperature ratings.

Installation Dimensions and Components

Illustrates components and provides installation dimensions for the sprinkler.

Hydraulic Design Criteria

Lists flow, pressure, and coverage data for hydraulic calculations.

Reliable F1 Res30 CCP Conical Concealed Pendent Sprinkler

Technical Specifications and Cover Plates

Details technical specs, cover plates, and temperature ratings.

Installation Dimensions

Illustrates installation dimensions for CCP and FP escutcheons.

Hydraulic Design Criteria

Lists flow, pressure, and coverage data for CCP/FP sprinklers.

Reliable F1 Res49 CCP Conical Concealed Pendent Sprinkler

Technical Specifications and Cover Plates

Details technical specs, cover plates, and temperature ratings.

Installation Dimensions

Illustrates installation dimensions for CCP and FP escutcheons.

Hydraulic Design Criteria

Lists flow, pressure, and coverage data for CCP/FP sprinklers.

Reliable F1 Res58 CCP Conical Concealed Pendent Sprinkler

Technical Specifications and Cover Plates

Details technical specs, cover plates, and temperature ratings.

Installation Dimensions

Illustrates installation dimensions for CCP and FP escutcheons.

Hydraulic Design Criteria

Lists flow, pressure, and coverage data for CCP/FP sprinklers.

Reliable F1 Res76 CCP Conical Concealed Pendent Sprinkler

Technical Specifications and Cover Plates

Details technical specs, cover plates, and temperature ratings.

Installation Dimensions

Illustrates installation dimensions for CCP and FP escutcheons.

Hydraulic Design Criteria

Lists flow, pressure, and coverage data for CCP/FP sprinklers.

Reliable F1 Res44 Horizontal Sidewall Sprinkler

Technical Specifications and Escutcheons

Details technical specs, escutcheons, and temperature ratings.

Installation Dimensions

Illustrates installation dimensions for horizontal sidewall sprinklers.

Hydraulic Design Criteria

Lists flow, pressure, and coverage data for sidewall sprinklers.

Reliable F1 Res44 SWC Conical Concealed Horizontal Sidewall Sprinkler

Technical Specifications and Cover Plates

Details technical specs, cover plates, and temperature ratings.

Installation Dimensions

Illustrates installation dimensions for SWC concealed sprinklers.

Hydraulic Design Criteria

Lists flow, pressure, and coverage data for SWC sprinklers.

Reliable F1 Res58 Horizontal Sidewall Sprinkler

Technical Specifications and Escutcheons

Details technical specs, escutcheons, and temperature ratings.

Installation Dimensions

Illustrates installation dimensions for sidewall sprinklers.

Hydraulic Design Criteria

Lists flow, pressure, and coverage data for sidewall sprinklers.

Reliable F1 Res58 HSWX Horizontal Sidewall Sprinkler

Technical Specifications and Escutcheons

Details technical specs, escutcheons, and temperature ratings.

Installation Dimensions

Illustrates installation dimensions for HSWX sidewall sprinklers.

Hydraulic Design Criteria

Lists flow, pressure, and coverage data for HSWX sprinklers.

Sprinkler Finishes and Installation

Standard and Special Application Finishes

Details available standard and special finishes for sprinklers and escutcheons.

Installation Guidelines

Provides guidelines for installing sprinklers, including wrench usage and torque.

Sprinkler Maintenance and Ordering Information

Maintenance Recommendations

Outlines inspection, cleaning, and replacement procedures for sprinklers.

Ordering Information

Specifies details required when ordering sprinklers and related components.

Summary

Reliable F1 Res Sprinkler Features

cULus Listed Residential Sprinklers

Identifies sprinklers as cULus Listed for residential use.

Pendent and Horizontal Sidewall Orientations

Details available sprinkler orientations for different installations.

Reliable F1 Res30 Residential Pendent Sprinkler

Technical Specifications and Materials

Details technical specs, materials, finishes, and temperature ratings.

Installation Dimensions and Components

Illustrates components and provides installation dimensions for the sprinkler.

Hydraulic Design Criteria

Lists flow, pressure, and coverage data for hydraulic calculations.

Reliable F1 Res49 Residential Pendent Sprinkler

Technical Specifications and Materials

Details technical specs, materials, finishes, and temperature ratings.

Installation Dimensions and Components

Illustrates components and provides installation dimensions for the sprinkler.

Hydraulic Design Criteria

Lists flow, pressure, and coverage data for hydraulic calculations.

Reliable F1 Res58 Residential Pendent Sprinkler

Technical Specifications and Materials

Details technical specs, materials, finishes, and temperature ratings.

Installation Dimensions and Components

Illustrates components and provides installation dimensions for the sprinkler.

Hydraulic Design Criteria

Lists flow, pressure, and coverage data for hydraulic calculations.

Reliable F1 Res76 Residential Pendent Sprinkler

Technical Specifications and Materials

Details technical specs, materials, finishes, and temperature ratings.

Installation Dimensions and Components

Illustrates components and provides installation dimensions for the sprinkler.

Hydraulic Design Criteria

Lists flow, pressure, and coverage data for hydraulic calculations.

Reliable F1 Res30 CCP Conical Concealed Pendent Sprinkler

Technical Specifications and Cover Plates

Details technical specs, cover plates, and temperature ratings.

Installation Dimensions

Illustrates installation dimensions for CCP and FP escutcheons.

Hydraulic Design Criteria

Lists flow, pressure, and coverage data for CCP/FP sprinklers.

Reliable F1 Res49 CCP Conical Concealed Pendent Sprinkler

Technical Specifications and Cover Plates

Details technical specs, cover plates, and temperature ratings.

Installation Dimensions

Illustrates installation dimensions for CCP and FP escutcheons.

Hydraulic Design Criteria

Lists flow, pressure, and coverage data for CCP/FP sprinklers.

Reliable F1 Res58 CCP Conical Concealed Pendent Sprinkler

Technical Specifications and Cover Plates

Details technical specs, cover plates, and temperature ratings.

Installation Dimensions

Illustrates installation dimensions for CCP and FP escutcheons.

Hydraulic Design Criteria

Lists flow, pressure, and coverage data for CCP/FP sprinklers.

Reliable F1 Res76 CCP Conical Concealed Pendent Sprinkler

Technical Specifications and Cover Plates

Details technical specs, cover plates, and temperature ratings.

Installation Dimensions

Illustrates installation dimensions for CCP and FP escutcheons.

Hydraulic Design Criteria

Lists flow, pressure, and coverage data for CCP/FP sprinklers.

Reliable F1 Res44 Horizontal Sidewall Sprinkler

Technical Specifications and Escutcheons

Details technical specs, escutcheons, and temperature ratings.

Installation Dimensions

Illustrates installation dimensions for horizontal sidewall sprinklers.

Hydraulic Design Criteria

Lists flow, pressure, and coverage data for sidewall sprinklers.

Reliable F1 Res44 SWC Conical Concealed Horizontal Sidewall Sprinkler

Technical Specifications and Cover Plates

Details technical specs, cover plates, and temperature ratings.

Installation Dimensions

Illustrates installation dimensions for SWC concealed sprinklers.

Hydraulic Design Criteria

Lists flow, pressure, and coverage data for SWC sprinklers.

Reliable F1 Res58 Horizontal Sidewall Sprinkler

Technical Specifications and Escutcheons

Details technical specs, escutcheons, and temperature ratings.

Installation Dimensions

Illustrates installation dimensions for sidewall sprinklers.

Hydraulic Design Criteria

Lists flow, pressure, and coverage data for sidewall sprinklers.

Reliable F1 Res58 HSWX Horizontal Sidewall Sprinkler

Technical Specifications and Escutcheons

Details technical specs, escutcheons, and temperature ratings.

Installation Dimensions

Illustrates installation dimensions for HSWX sidewall sprinklers.

Hydraulic Design Criteria

Lists flow, pressure, and coverage data for HSWX sprinklers.

Sprinkler Finishes and Installation

Standard and Special Application Finishes

Details available standard and special finishes for sprinklers and escutcheons.

Installation Guidelines

Provides guidelines for installing sprinklers, including wrench usage and torque.

Sprinkler Maintenance and Ordering Information

Maintenance Recommendations

Outlines inspection, cleaning, and replacement procedures for sprinklers.

Ordering Information

Specifies details required when ordering sprinklers and related components.

Overview

The Reliable Model F1Res Series Glass Bulb Residential Sprinklers are cULus Listed residential sprinklers designed for fast thermal response, meeting UL 1626 requirements. They are intended for installation in accordance with NFPA 13, 13R, and 13D, and are suitable for use in residential occupancies or residential portions of any occupancy where permitted. These sprinklers are listed for use in wet systems only.

Function Description:

These sprinklers utilize a 3 mm glass bulb operating element and are available in both pendent and horizontal sidewall orientations. They are engineered to provide a minimum design density of 0.1 gpm/sf (4.1 mm/min) for NFPA 13 applications, with flow and pressure never falling below the minimums specified in the Listed Design Criteria tables. For NFPA 13R and 13D applications, the design flow and pressure must meet or exceed the specified minimums.

Important Technical Specifications:

General:

  • Style: Pendent, Recessed Pendent, Conical Concealed Pendent, Sidewall, Recessed Sidewall, Conical Concealed Sidewall.
  • Threads: 1/2" NPT or ISO7-1R1/2 (for most models), 3/4" NPT or ISO7-1R3/4 (for F1Res76 and F1Res76 CCP).
  • Nominal K-Factor: Varies by model:
    • F1Res30/F1Res30 CCP: 3.0 (43 metric)
    • F1Res49/F1Res49 CCP: 4.9 (71 metric)
    • F1Res58/F1Res58 CCP/F1Res58 HSW/F1Res58 HSWX: 5.8 (84 metric)
    • F1Res76/F1Res76 CCP: 7.6 (109 metric)
    • F1Res44 HSW/F1Res44 SWC: 4.4 (63 metric)
  • Max. Working Pressure: 175 psi (12 bar) for all models.
  • Sensitivity: Fast-response.
  • Temperature Ratings: 155°F (68°C) and 175°F (79°C). Note that for SWC Conical Concealed Horizontal Sidewall Sprinklers, the 175°F (79°C) rating is not for installation where the maximum ceiling temperature exceeds 100°F due to cover plate temperature rating.

Material Specifications (Common to most models):

  • Thermal Sensor: 3 mm glass bulb.
  • Sprinkler Frame: Brass Alloy.
  • Button: Copper Alloy.
  • Sealing Assembly: Nickel Alloy with PTFE.
  • Load Screw: Bronze Alloy.
  • Deflector: Bronze Alloy.

Coverage Area and Hydraulic Design Criteria (Examples):

  • F1Res30 Pendent: Max. 16x16 ft (4.9x4.9 m) with 13 gpm (49 l/min) at 18.8 psi (1.3 bar). Deflector to ceiling distance: 1 to 4 inches (25 to 100 mm).
  • F1Res30 CCP Pendent: Max. 14x14 ft (4.3x4.3 m) with 11 gpm (38 l/min) at 13.4 psi (0.92 bar). Deflector to ceiling distance: 1/2 to 1 inch (13 to 25 mm).
  • F1Res49 Pendent: Max. 20x20 ft (6.1x6.1 m) with 20 gpm (76 l/min) at 16.7 psi (1.15 bar) for 1-4 inch deflector distance, or 22 gpm (83 l/min) at 20.2 psi (1.39 bar) for 4-8 inch deflector distance.
  • F1Res44 HSW (Horizontal Sidewall): Max. 16x20 ft (4.9x6.1 m) with 23 gpm (87 l/min) at 27.4 psi (1.89 bar) for both 4-6 inch and 6-12 inch deflector distances.
  • F1Res58 HSWX (Horizontal Sidewall): Max. 14x26 ft (4.3x7.9 m) with 42 gpm (160 l/min) at 52.4 psi (3.63 bar) for 4-6 inch deflector distance, or 46 gpm (174 l/min) at 62.9 psi (4.34 bar) for 6-12 inch deflector distance.

Usage Features:

  • Decorative Finishes: Available with various finishes, including recessed escutcheons (F1, F2, FV, FP) and conical concealed cover plates (CCP, SWC, SWC-2).
  • Escutcheon Compatibility: Specific recessed escutcheons (F1, F2, FV, FP) are designated for use with Model F1Res sprinklers. Not all F1Res sprinklers are compatible with all escutcheons; users must confirm listing for individual sprinklers. Model FV escutcheons and CCP cover plates are not for use in positively pressurized ceiling plenums.
  • Installation: Sprinklers must be installed as shown in the bulletin. For wall or ceiling installations, a hole diameter of 2-1/4" (57 mm) is required for F1 or F2 recessed escutcheons, and 2-5/8" (67 mm) for FP recessed escutcheons, CCP, SWC, and SWC-2 cover plates.
  • Torque Recommendations:
    • 1/2" NPT and ISO7-1R1/2: 8-18 ft-lbs (11-24 N-m).
    • 3/4" NPT and ISO7-1R3/4: 14-20 ft-lbs (19-27 N-m).
    • Over-tightening can cause leakage or impairment.
  • Horizontal Sidewall Installation: F1Res HSW sprinklers require the flow arrow on the deflector to point away from the near wall and the "Top" marking to face the ceiling.

Maintenance Features:

  • Regular Inspection: Sprinklers and the system must be inspected and maintained in accordance with NFPA 25, 13, 13D, and 13R, as well as local Authority Having Jurisdiction requirements.
  • Storage: Sprinklers should remain in their original cartons and packaging until installation to prevent damage.
  • Cleaning: Dust can be removed by gentle vacuuming without touching the sprinkler. Do not use soap, water, ammonia liquid, or other cleaning fluids.
  • Replacement:
    • Replace any sprinkler that has been painted (other than factory applied).
    • Replace any damaged sprinkler, or one with cracks in the glass bulb, or where liquid has been lost from the glass bulb.
    • Properly installed CCP, SWC, and SWC-2 cover plates require an air gap for proper operation; this gap should not be sealed or painted.
  • Spare Stock: A stock of spare sprinklers should be maintained for quick replacement of damaged or operated units.
  • Bulb Protectors: Glass bulb sprinklers come with orange bulb protectors to prevent damage during shipping and handling. These protectors must be removed only when the sprinkler system is placed in service, by undoing the clasp by hand. RASCO wrenches are designed for installation with protectors in place.
  • Wrenches: Only Model W2 (for pendent and HSW) or Model W4 (for recessed and concealed) wrenches should be used. Using other wrenches may damage the sprinklers. The Model W4 wrench has two sets of jaws, one equivalent to a Model GFR2 wrench and the other to a Model W1 wrench. The smallest set of jaws that fits the sprinkler's wrench flats should be used with a nominal 1/2" square drive ratchet and 5" (125mm) extension.

Reliable F1Res Series Specifications

General IconGeneral
BrandReliable
ModelF1Res Series
CategoryIrrigation System
LanguageEnglish

Related product manuals