Operating and
installation instructions
Read the instructions prior to performing any task!
REMKO RKL DC series
RKL 495 DC
Local room air conditioner in split design
0240-2019-12 Edition 1, en_GB

Questions and Answers

  • T
    Tammy JuarezAug 5, 2025
    What to do if my REMKO RKL 495 DC does not start?
    • A
      Alison WashingtonAug 5, 2025
      If your REMKO Air Conditioner doesn't start, there might be several reasons: * There could be a power failure. Check the voltage and wait until it is turned on again, if necessary. * The mains fuse or controller fuse might be faulty. Arrange to have it exchanged. * The power plug might not be inserted in the socket. Ensure the power plug is properly inserted. * The condensate container might be full, with a flashing "DRAIN WATER" display. Empty the container via the condensate drain hose. * The timer mode might be activated. Wait for the timer period to expire or press the "I / 0" key again.
  • A
    Ashley BassAug 9, 2025
    Why is my REMKO Air Conditioner working with reduced performance?
    • M
      mccalllarryAug 9, 2025
      If your REMKO Air Conditioner is working with reduced performance, check the following: * Ensure that the exhaust air or outlet openings are not dirty or blocked. Clean the openings and remove any foreign objects. * The filter might be soiled. Clean the filter according to the instructions. * The outdoor unit might be dirty. Clean the fins on the inside of the outdoor unit. * The cooling load of the room might be excessive. Reduce the thermal load.
  • M
    Michael HarrisAug 14, 2025
    What to do if condensate leaks out of my REMKO Air Conditioner?
    • S
      Stanley FitzpatrickAug 14, 2025
      If condensate leaks from your REMKO Air Conditioner, check if: * The unit is standing at an angle. Position it vertically and ensure it has a stable base. * The stopper in the condensate drain hose is missing. Seal the hose so that it is watertight again.
  • N
    Nancy TrevinoAug 18, 2025
    What does error code 32# mean on my REMKO RKL 495 DC Air Conditioner?
    • M
      Matthew GeorgeAug 18, 2025
      Error code 32# on your REMKO Air Conditioner indicates a defective liquid line probe or excessive liquid line temperature. If the error appears less than 1 minute after turning on the unit, the THOP probe (PCB 3) is defective and needs replacement. If the error appears after operating for some time, it could be due to a lack of refrigerant or a malfunctioning fan motor in the outdoor unit. If the temperature on the THOP probe rises above 58 °C, the unit will switch off and display error code "32".
  • E
    Eduardo HernandezAug 22, 2025
    How to fix error code 01# on REMKO RKL 495 DC Air Conditioner?
    • A
      allenhollandAug 22, 2025
      Error code 01# on a REMKO Air Conditioner indicates a communication error between the circuit board on the indoor unit and the outdoor unit. To resolve this, check the 6-wire connection and plug contacts CN202 (PCB 2) - CN109 (PCB 3). If necessary, replace the connecting cable or the motherboard (PCB 3).
  • R
    Rebekah MorrisAug 27, 2025
    What does error code 02# mean for REMKO RKL 495 DC Air Conditioner?
    • R
      rogerjohnsonAug 27, 2025
      Error code 02# on your REMKO Air Conditioner means that the ambient temperature probe is defective. Replace the THRA probe (PCB 2).
  • E
    Emily JacksonAug 30, 2025
    What does error code 03# mean on a REMKO RKL 495 DC Air Conditioner?
    • A
      ashleymurphyAug 30, 2025
      Error code 03# on your REMKO Air Conditioner indicates that the evaporator probe is defective. Replace the THEP probe (PCB 2).

Summary

Safety and Usage Instructions

General Safety Notes and Identification

Covers general safety guidelines, hazard warnings, and the explanation of symbols and signal words used in the manual for safe operation.

Dangers of Non-Compliance and Safe Working

Details risks from ignoring safety notes, emphasizing safe working practices and adherence to regulations for accident prevention.

Operation

Control Panel and Remote Operation Overview

Details the unit's operation via the control panel and infrared remote, explaining buttons, LEDs, display, and timer functions.

Operating Modes: Cooling, Dehumidifying, Circulated Air

Explains the specific procedures for operating the unit in Cooling, Dehumidifying, and Circulated Air modes, including setup and settings.

Installation

Installation Basics and Indoor Unit Setup

Covers general installation instructions, indoor unit positioning, and requirements for connector pipes, including routing and protection.

Connecting Line

Electrical Wiring

Troubleshooting

Operational Malfunctions and Remedies

Lists common operational malfunctions, their causes, and recommended remedies for the unit, such as power failure or reduced performance.

Error Codes and Troubleshooting

Details specific error codes displayed by the unit and their corresponding possible causes and suggested solutions for troubleshooting.

Advanced Error Code Analysis

Continues the list of error codes, providing detailed explanations for issues related to probes, compressor, IPM circuit board, and power supply.

Care and Maintenance

General Care and Filter Maintenance

Outlines regular care procedures, emphasizing unit cleaning, filter maintenance, and the importance of specialized servicing for long-term operation.

Shutdown

REMKO RKL 495 DC Specifications

General IconGeneral
BrandREMKO
ModelRKL 495 DC
CategoryAir Conditioner
LanguageEnglish