E1/E20/E2/E2 Lite Additional Document    1. Overview 
R20UT1994EJ0910  Rev.9.10    Page 12 of 59 
Oct.06.23   
Table 1-3   Assignments of the External Trigger Input and Output Pins for the E2 Expansion Interface 
Pin Nos. 1 to 8 are not used. 
These pins must be left open-circuit. 
3   
4   
7   
8   
External trigger output (ch. 0) 
External trigger output (ch. 1) 
11  Input  External trigger input (ch. 0) 
12  Input  External trigger input (ch. 1) 
A pin for output of the power-supply voltage for the E2 expansion interface 
(1.8 V to 5.0 V) 
 
1.5.2  Specifications of the External Trigger Inputs and Outputs 
 
Table 1-4  Specifications of the External Trigger Inputs and Outputs 
E2 expansion interface: 2 (ch. 0: pin 11, ch. 1: pin 12) 
Output signal channels  E2 expansion interface: 2 (ch. 0: pin 9, ch. 1: pin 10) 
Voltage of the E2 expansion 
interface 
•  When the power is supplied from the emulator: voltage to be supplied 
(any voltage from 1.8 V to 5.0 V, as specified in the debugger) 
•  When the power is not supplied from the emulator: VDD voltage 
Conditions for detecting an 
external trigger input 
Detecting edges (rising, falling, or both) 
Detecting a level (low or high) 
Operation during the input of an 
external trigger 
Recording the data from measuring the current consumption while the low 
or high level is being input 
Condition for detecting an 
external trigger output 
Detecting a break or a trigger condition for measuring the current 
consumption 
Operation during the output of 
an external trigger 
When a break is detected, a low- or high-level pulse is output (the pulse 
width can be set to times in the range from 1 µs to 65535 µs). 
When a trigger condition for measuring the current consumption is 
detected, a high-level pulse is output (the pulse width can be set to times 
in the range from 1 µs to 65535 µs). Otherwise, a high level is output while 
a condition is being satisfied. 
Note:  About 12 µs will be required from the detection of a condition for an external trigger input being satisfied until the 
user program is stopped.