RL78/G13 Safety Function (Frequency Detection)
5.8.17 Getting Pulse Interval Measurement Value
Figure 5.20 shows the flowchart for getting the pulse interval measurement value.
R_TAU0_Channel5_
Get_PulseWidth
()
Obtain pulse interval measurement
value
[Argument]
uint32_t *width
*width
g_Tau0Ch0Width
g_Tau0Ch0Width: Global variable which contains pulse
interval measurement value
return
Figure 5.20 Getting Pulse Interval Measurement Value
R01AN0956EJ0100 Rev. 1.00 Page 48 of 70