25
Parameters Number
Parameter Name Description
Set options
[08] GEL
[08] FLd
[08]
LF14
LF15
LF16
Gel lead-acid battery, constant
voltage charging 56.8V,float
charging voltage 55.2V
Lithium iron phosphate battery
corresponding to 14 strings, 15
strings and 16 strings
Default constant voltage charging
voltage
14 strings: 50.4V
15 strings: 54V
16 strings: 57.6V
[08]
n14
n13
Default constant voltage charging
voltage
13 strings: 53.2V
14 strings: 57.2V
Lithium-ion battery corresponding
to 12 strings, 13 strings and 14
strings
Battery type
[08] SLd
(Default)
Sealed lead-acid/AGM battery,
constant voltage charging 58.4V,
float charging voltage 55.2V
08
[08] USE
User-defined, all battery parame-
ters can be set
Flooded lead-acid battery,constant
voltage charging 58.4V,float
charging voltage 55.2V
[09] 58.4
(Default)
Changes the charging voltage
setting, set the range 48V to 58.4V,
in 0.4V increments
Boost Charge
Voltage
*available in USER
and lithium setting
only
09
10
[10] 120 min
(Default)
Raise the boost charge time
setting, refers to the constant
voltage charging reached at
Program 09 . The range is 5min
to 900min, in 5 minute increments
Boost Charge
Duration
*available in USER
setting only
11
[11] 55.2V
(Default)
Floating charging voltage set
range 48V to 58.4V, in 0.4V
increments
Float Charge
Voltage
*available in USER
setting only