07
Alarm
—If there is a buzzing sound, the battery is low. The user should reduce the
AC load, charge the battery, and check the DC cable for excessive losses.
Fault LED (Red)
— The red indicator turns on as the inverter shuts down due to overheating,
overload, under voltage, or over voltage.
Immediately turn off all AC appliances if the Fault LED is lit. Allow the inverter to cool
before continuing. Make sure that the ventilation vents are not blocked.
If an inverter shutdown was preceded by a buzzing sound, there may be an excessive
load in combination with low voltage or a cable problem.
ON/OFF Switch
— Controls AC output.
AC Outlets
—
USB Power Port
— 5 volts / 2.1A for charging tablets, smartphones, and other small
Remote Switch Connection
— Insert wired remote switch to the connection port. Set
electronic devices.
NOTE
4.
5.
6.
7.
8.
115V AC 60Hz, up to 15amps for 2000W and 3000W models, up to 6.1
amps for 700W,up to 8.7 amps for 1000W.
ON/OFF switch to "remote" position.