A.G.M 2
14.6V
13.7V
4
Sealed Lead Acid
14.4V
13.6V
5
Gel 2
14.4V
13.8V
6
Flooded Lead Acid
14.8V
13.8V
7
Calcium (Open)
15.1V
13.6V
8
Equalization
15.5V for 4 hrs.
9
Not Used
N/A
N/A
Battery Charging Stages
Bulk Stage: The charger will supply constant current until the battery voltage reaches
the boost voltage. The software will calculate the time charging began up until the
battery voltage reaches 0.3V below the boost voltage. It uses this time to as T0 and
T0×10 = T1.
Boost Stage: The charger will supply constant voltage and reduce the current slowly
through this stage. The charger will stay in this stage until T1 has run out. After this time
the charger will enter the float stage. This stage will last between 1 hour and 12 hours
depending on T1.
Float Stage: During this stage the charger will supply a constant voltage which is
determined by the battery selected and will keep current at a minimum. This stage acts
as a trickle charger.