32
General
Model
Dimensions
4 x Ø10mm
Net Weight
RVR60
Working Temperature
Humidity Range
Enclosure
< 3000m
Communication
Certifications
RS232 RS485
ETL Listed to UL1741
-35°C to +45°C
≤ 95% (NC)
IP32
Altitude
285 x 205 x 102mm (11.2 x 8.1 x 4.0in)
Mounting Holes
Max Terminal Size
4 AWG25mm
2
3.6 kg 7.9 lbs
Battery Charging Parameters
Battery GEL SEALED FLOODED LI (LFP) USER
High Voltage
Disconnect
16 V 16 V 16 V 16 V
Equalization
Voltage
----- -----
14.6 V
Boost Voltage
Float Voltage 13.8 V 13.8 V 13.8 V -----
Boost Return
Voltage
13.2 V 13.2 V 13.2 V 13.2 V
Low Voltage
Reconnect
12.6 V 12.6 V 12.6 V 12.6 V
Under Voltage
Warning
12 V 12 V 12 V 12 V
Low Voltage
Disconnect
Equalization
Duration
2 hours 2 hours
Over-Discharge
Delay Time
Boost Duration
2 hours 2 hours 2 hours -----
----------
9-17 V
9-17 V
9-17 V
0-10 Hrs.
Equalization
Interva
30 Days 30 Days
----------
0-250 Days
1-10 Hrs.
9-17 V
9-17 V
9-17 V
9-17 V
9-17 V14.8V
14.4 V14.6 V 14.4 V 14.2 V
11.0V 11.0V 11.0V 11.0V
1-30 s5 s 5 s 5 s 5 s