3. FCC COMPLIANCE
2. SAFETY INSTRUCTIONS
Warning: Please Read This Manual Before Installaon. Any Damage To The Product Due To
Not Following This Manual Is Not Covered By The Warrantee. All The Installaon Should Be
Done By A Cerfied Electrician. Besides The Cable Connectors, Nothing Else On Or In
Microinverter Should Be Modified.
All Installaons Should Follow The Local Electriccodes. The Replus-250/ Replus-250A/B Does Not
Include Components That Can Be Served By Customers. Opening Or Aempng To Modify Or
Change The Construcon Or Design Of The Microinverter Shall Void The Warranty. Please Contact
Authorized Service Agents For Any Service Work.
Replus-250/ Replus-250A/B Is A Grid-ed Solar Inverter. It May Require Approval From Local
Ulity Company Prior To Grid Inter Connecon.
This equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protecon
against harmful interference in a residenal installaon. This equipment can radiate energy from
radio frequencies and, if not installed and used in accordance with the instrucons, may cause
harmful interference with radio communicaons. If this equipment does cause harmful
interference to radio or television recepon, which can be determined by turning the equipment
off and on, the user is encouraged to aempt to correct interference by taking one or more of
the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separaon distance between the equipment and the receiver.
• Connect the equipment to an outlet on a circuit different from that to which the receiver is
connected.
• Consult the dealer or an experienced radio/TV technician for help.
Changes or modificaons not expressly approved by the party responsible for compliance may
void the user’s authority to operate the equipment.
4. INSTALLATION
Warning: Be Aware That Installaon Of This Equipment Includes Risk Of Electric Shock.
Normally, Grounded Conductors Maybe Ungrounded And Energized When A Ground Fault
Is Indicated.
Parts Included
In addion to the Replus-250/ Replus-250A/B micro inverters, PV modules, rack, and associated
hardware, you’ll need the Replus-250/ Replus-250A/B installaon kit. This kit includes the
following items:
• Installaon fixed screws
• Grounding fixed washers
• User manual
• Warranty Terms and Warranty Card
Other Required Parts And Tools
In addion to your PV array and its associated hardware, you will need to provide the following:
• Juncon box
• Connuous grounding wire
• Number 2 Phillips screwdriver
• Sockets and wrenches for mounng hardware
• Torque wrench
• Mounng hardware suitable for module rack
Lightning Surge Suppression
Lightning does not actually need to strike the equipment or building where a PV system is
installed to cause damage. Oen, a strike nearby will induce surges in the electrical grid that can
potenally exceed maximum voltages and damage equipment. The Replus-250/ Replus-250A/B
has integral surge protecon, greater than most string inverters. However, if the surge has
sufficient energy, the protecon built into the Replus-250/ Replus-250A/B can be exceeded, and
the equipment can be damaged.
The ReneSola Limited Warranty does not cover “acts of God” such as lightning strikes, and since
lightning strikes can occur any where, it is recommended to install surge protecon as part of any
solar installaon. Installaon of surge protecon devices should follow vendor instrucons.