10.8.7. Return Leakage Penalty
This is the estimated fraction of energy loss of the return side. The default value is 0.5, which assumes
that of the return air leakage, about half of its energy is lost to outdoors (i.e., the other half of its energy
stays inside the house). This number can be raised if you suspect that there is actually more energy loss
to the outdoors from the return side. For example, if the return goes through a very cold crawl space,
the return leakage would pull in cold air and have a greater effect on the annual HVAC losses.
10.9 Save the Duct Leakage Test Report as a PDF file
10.9.1. With Office 2007:
Click the MS Office icon at the top left corner of the window:
Mouseover “Save As” on the menu Click “PDF or XPS”
Select the directory to save the PDF file to Enter a proper file name for the PDF file to as
Click “Publish”
10.9.2. With Office 2010
Click "File" "Save As" Change the "Save as type" to "PDF "
Select the directory to save the PDF file to Enter a proper file name for the PDF file to as Click "Save"