10
The fuel supply system must be bled in conjunction with the initial start-up
or when the fuel runs out.
• Place a suitable small collection container under the fuel pump.
• Open the wing screw at the bottom of the fuel pump by 2–3 rotations.
• Connect the power cord to the power socket and press the Reset switch on the plug to
connect power to the heater.
• Press the heaters activation switch (Power).
• The fuel pump is activated, discharging fuel and air bubbles from the bleed opening. Close
the bleeding screw.
• If the fuel hose contains a lot of air, you may need to repeat the above steps two or three
times.
• If the burner shuts down due to a lack of fuel or there is another cause to suspect that air
has entered the fuel supply circuit, you must repeat the bleeding in accordance with these
instructions.
• Should you wish to avoid bleeding in the future, do not let the fuel tank drain fully at any
point.
BLEEDING THE FUEL SUPPLY SYSTEM
air hole
open
close
air release
switch