TM061 Rheem 27 Water Star Service Instructions – Issued: 11/10
REV A Issued 08/13
This document is stored and maintained electronically by Service. All printed copies not bearing this statement in RED are deemed “uncontrolled”
Diagnostic Points on Printed Circuit Board
2 – 5 VDC (pulse)
>1310 pulses/minute
Water Flow Sensor pulse signal.
(Only when water is flowing)
Fan Motor has proper voltage.
Fan Motor has proper voltage.
4 – 10 VDC (Pulse)
>4800 pulses/minute
Fan Motor producing a regular pulse.
Refer to thermistor
resistance chart on following
page.
Cold water inlet thermistor.
Heat exchanger thermistor.
Hot water outlet thermistor.
Flame rod not detecting flame.
Flame rod detecting flame.
PGFR (Proportional Gas Flow
Regulating Valve)
GISV 0 (Gas Inlet Solenoid Valve 0)
(Primary fuel inlet to gas valve)
Solenoid valve (SV1)
(Fuel to ODS and front right burner)
Solenoid valve (SV2)
(Fuel to back right burner)
Solenoid valve (SV3)
(Fuel to left side burner)
Water volume control motor has
proper voltage.
Water volume control motor has
proper voltage.
Less than 1VDC (Limiter on)
4 – 6VDC (Limiter Off)
Water volume control motor position
switch is normal.
Water bypass control motor has
proper voltage.
Water bypass control motor has
proper voltage.
Less than 1VDC (Limiter on)
4 – 6VDC (Limiter Off)
Water bypass control motor position
switch is normal.