EasyManua.ls Logo

Rheem 874W27NF - Error Code 51: False Flame Detected

Rheem 874W27NF
61 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
37
TM061 Rheem 27 Water Star Service Instructions Issued: 11/10
REV A Issued 08/13
This document is stored and maintained electronically by Service. All printed copies not bearing this statement in RED are deemed “uncontrolled”
Error Code 51
False Flame Detected.
Error Code 51, 72, 80
Display maintenance information
0y‟ on remote control.
Replace gas valve assembly.NO
Does the flame extinguish
completely after shut down?
Does flame detection
maintenance information „0y‟
indicate 01?
YES
Clean or replace the flame rod
electrode.
NO
Replace the control PCB.
YES
Does flame detection
maintenance information „0y‟
indicate 01?
Isolate power supply for 10
seconds to clear error code.
Restore power. Continue fault
diagnosis if an error reoccurs.
Detach flame sensor connector
from terminal U on control PCB.
Display maintenance information
0y‟ on remote control.
YES
NO

Related product manuals