92-24161-66-03
SUPERSEDES 92-24161-66-02
INSTALLATION INSTRUCTIONS
FOR HIGH EFFICIENCY CONDENSING GAS FURNACES
90RS, 90RT UPFLOW SERIES
90TS DOWNFLOW/HORIZONTAL SERIES
U.L. recognized fuel gas and CO (carbon monoxide) detectors are recommended in all
applications, and their installation should be in accordance with the manufacturer’s
recommendations and/or local laws, rules, regulations, or customs.
Upflow Models Downflow/Horizontal Models
Model Number Input (Btu) Tons Model Number Input (Btu) Tons
90RS04EES** 45,000 3 90TS04EES** 45,000 3
90RS06EES** 60,000 3 90TS06EES** 60,000 3
90RT07EES** 75,000 3 90TS07EES** 75,000 3
90RT07EFS** 75,000 4 90TS07EFS** 75,000 4
90RS09EJS** 90,000 4 90TS09EJS** 90,000 4
90RS09EGS** 90,000 5 90TS09EGS** 90,000 4.5
90RS10EGS** 105,000 4.5 90TS10EGS** 105,000 4.5
90RS12EHS** 120,000 5 90TS12EHS** 120,000 5
Question and Answer IconNeed help?

Do you have a question about the Rheem 90RS12EHS Series and is the answer not in the manual?

Rheem 90RS12EHS Series Specifications

General IconGeneral
Series90RS12EHS
Model Number90RS12EHS
CategoryFurnace
ConfigurationUpflow/Horizontal
Efficiency90% AFUE
Input BTU120, 000
Output BTU108, 000
StagesSingle Stage
IgnitionHot Surface Ignition
Fuel TypeNatural Gas
Vent TypeDirect Vent
Warranty10-Year Limited Warranty

Summary

Safety Information

General Safety Warnings

Provides critical safety warnings and precautions for furnace installation and operation.

Clearances

Venting and Combustion Air

Combustion and Ventilation Air

Requirements for providing adequate combustion and ventilation air for furnace operation.

Vent Pipe Installation

Guidelines and procedures for installing vent pipes, including non-direct and alternate terminations.

Direct Vent Installation Guidelines

Specific installation requirements for direct vent systems, including piping, terminations, and kits.

Gas Supply and Piping

Gas Supply Requirements

Information on natural gas and LP gas requirements, conversion kits, and safety precautions for gas supply.

Gas Piping Installation

Guidelines for installing gas piping according to local codes, including pipe sizing, shut-off valves, and drip legs.

Electrical Wiring

General Electrical Safety

Critical safety warnings regarding electrical connections, grounding, and safety switches.

High Altitude Instructions

High Altitude Conversion Kits

Details on high altitude conversion kits, their contents, and application for specific furnace models.

Start-Up Procedures

Setting Input Rate

Air Flow

Temperature Rise Check

Procedure for checking air flow correctness by measuring temperature rise across the heat exchanger.

Troubleshooting

Troubleshooting Start-Up

Troubleshooting steps for furnace start-up issues related to the Integrated Furnace Control (IFC).

Troubleshooting Ignition Trials

Diagnosing problems during the ignition trial phase, including spark and flame sensing issues.

Wiring Diagrams