INSTALLATION INSTRUCTIONS
FOR 4 POSITION CONDENSING TWO-STAGE,
COMMUNICATING GAS FURNACES W/ECM BLOWER
(-)96V SERIES
& (-)(-)96MDV SERIES
U.L. and/or C.S.A. recognized fuel gas and CO (carbon monoxide) detectors are rec-
ommended in all applications, and their installation should be in accordance with the
manufacturer’s recommendations and/or local laws, rules, regulations, or customs.
92-24161-124-07
SUPERSEDES 92-24161-124-06
Factory Use Only

Table of Contents

Questions and Answers

  • T
    Tammy PageAug 12, 2025
    Why does my Rheem 96MDV Furnace flame keep going out?
    • D
      Daniel ThompsonAug 12, 2025
      The flame in your Rheem Furnace might be going out due to several reasons. The flame sense rod may need cleaning, be improperly connected, or have wiring issues. The flame sensor may be poorly grounded or mounted. Also, an unstable flame pattern may be the cause. To resolve this, clean or replace the flame sense rod, check all connections and wiring, reinstall or replace the flame sensor, ensuring proper grounding, and verify that all burner assembly components are correctly installed with good seals.
  • C
    Carla BradfordAug 16, 2025
    What does it mean when my Rheem Furnace displays 'No Valid Model Data on Memory Card'?
    • S
      spencermillerAug 16, 2025
      This message on your Rheem Furnace indicates that the memory card is either blank, missing, or corrupted. Remove the memory card and replace it with the original memory card from the furnace or the correct replacement memory card. Never replace the memory card of a furnace with a memory card from another furnace or component. If the original memory card for the furnace control is available and working, it must be used. A correct replacement memory card can be ordered from ProStock. Be sure to have the furnace model and serial number available when ordering.
  • B
    belldanielAug 19, 2025
    How to fix 'No Model Data' error on my Rheem Furnace?
    • J
      jeff16Aug 19, 2025
      The 'No Model Data' error on your Rheem Furnace typically means the memory card is missing. Replace the missing memory card into the connector labeled P6 on the furnace control (I.F.C.). If the original card cannot be found, order a replacement from ProStock, ensuring it's the correct one for your furnace. Remember to cycle the furnace power off and on after replacing the card.
  • M
    morrisonnicoleAug 23, 2025
    What to do if the over-temperature switch is open in my Rheem 96MDV Furnace?
    • M
      moralesmaryAug 23, 2025
      If the over-temperature switch (roll-out) is open in your Rheem Furnace, it could be due to insufficient venting, loose or faulty wiring, or an unstable flame pattern. Ensure the pressure switches are not bypassed, the inducer operates at the proper RPM, venting does not exceed specified lengths, and there are no obstructions in combustion venting. Also, check that all gaskets between the inducer and center panel/heat exchanger are properly installed and sealed.
  • R
    Renee BrownAug 27, 2025
    How to fix an open fuse in my Rheem 96MDV Furnace?
    • O
      Oscar FergusonAug 28, 2025
      An open fuse in your Rheem Furnace typically indicates an electrical short from low voltage (24VAC) to ground or common. You should repair the short circuit and then replace the fuse.
  • J
    Jonathan SellersAug 31, 2025
    What to do if water is sensed in my Rheem 96MDV?
    • H
      harrisonjaredAug 31, 2025
      If your Rheem Furnace is sensing water, it could be due to a blocked condensate drain, damaged wiring to the sensors, or the water sensor being removed from the collector box. To address this, remove any blockage in the condensate drain, repair or replace the wiring between the IFC and both sensors, and return the sensor(s) to their proper location in the collector box.
  • K
    Kimberly YoungSep 4, 2025
    Why does my Rheem 96MDV Furnace show a horsepower conflict on the memory card?
    • C
      Christine MooreSep 4, 2025
      A horsepower conflict on the memory card of your Rheem Furnace can occur if the blower motor has been replaced with the wrong horsepower motor, or if the memory card or furnace control has been replaced with an incorrect one. Determine the correct motor and/or model data card for your furnace and replace the incorrect or damaged part with a new, correct part. Never replace the memory card of a furnace with a memory card from another furnace or component. If the original memory card for the furnace control is available and working, it must be used. A correct replacement memory card can be ordered from ProStock. Be sure to have the furnace model and serial number available when ordering.
  • T
    thorntonronaldSep 7, 2025
    What causes a low-pressure switch to close with the inducer off in a Rheem 96MDV?
    • R
      randymedinaSep 7, 2025
      A closed low-pressure switch with the inducer off in your Rheem Furnace may be caused by a faulty switch, a bypassed pressure switch, loose or faulty wiring, or abnormally high negative pressure on the vent system. Replace the low-pressure control (switch), remove any bypasses to restore correct operation, check wiring and connections, and inspect the venting system as defined in the furnace installation instructions.

Rheem 96MDV Series Specifications

General IconGeneral
Model Series96MDV Series
TypeGas Furnace
Fuel TypeNatural Gas or Propane
EfficiencyUp to 96% AFUE
Heat ExchangerStainless Steel
Cabinet TypeMulti-Position
Heating Capacity40, 000 to 120, 000 BTU/hr
Blower TypeVariable Speed
Vent TypeDirect Vent
WarrantyLimited Lifetime Heat Exchanger
StagesTwo-stage heating

Related product manuals