72
HOW TO REMOVE COMPONENTS
3.6 WATER CONTROL VALVE
NOTE: Before removing water inlet connec-
tion, turn off water to the water heater by
closing the shut off valve and drain the heater.
1. Remove user interface from the water heater.
NOTE: To remove the interface , refer to sec-
tion “3.13 Display".
2. Remove water control wiring harness from the
control board (connector “G”) and remove the two
white Molex connectors located rear of the user in-
terface.
3. Remove the four screws and two flange bracket.
Then, remove water inlet pipe and bypass pipe.
4. Remove quick fastener connected to check valve.
NOTE: for recirculation model, remove quick
fastener connected to water inlet connection.
5. Remove quick fastener connected to bypass valve.
Bypass Valve
Water Control Valve