AIR COOLED
CONDENSING UNITS
92-104921-09-07 (5/16)
Printed in USA
[ ] indicates metric conversions.
Do not destroy this manual.
Please read carefully
and keep in a safe place
for future reference by a
serviceman.
WARNING
THESE INSTRUCTIONS
ARE INTENDED AS AN AID
TO QUALIFIED, LICENSED
SERVICE PERSONNEL FOR
PROPER INSTALLATION,
ADJUSTMENT, AND
OPERATION OF THIS
UNIT. READ THESE
INSTRUCTIONS
THOROUGHLY
BEFORE ATTEMPTING
INSTALLATION OR
OPERATION. FAILURE
TO FOLLOW THESE
INSTRUCTIONS MAY
RESULT IN IMPROPER
INSTALLATION,
ADJUSTMENT, SERVICE,
OR MAINTENANCE
POSSIBLY RESULTING IN
FIRE, ELECTRICAL SHOCK,
PROPERTY DAMAGE,
PERSONAL INJURY, OR
DEATH.
INSTALLATION INSTRUCTIONS
(-)A13, (-)A14 & (-)A16 MODEL SERIES –
13, 14 & 16 SEER
WARNING:
RECOGNIZE THIS SYMBOL
AS AN INDICATION OF
IMPORTANT SAFETY
INFORMATION
ST-A1226-01-00
FEATURING INDUSTRY STANDARD
R-410A REFRIGERANT
earth friendly refrigerant
e
ar
t
h
r
y r
dly
dl
e
n
i
fr
h
NOTE: Actual unit appearance
may vary.

Table of Contents

Questions and Answers

  • K
    Kimberly RodriguezAug 18, 2025
    Why are the registers sweating in my Rheem Air Conditioner system?
    • B
      bishopamberAug 18, 2025
      If the registers in your Rheem Air Conditioner system are sweating, it's likely due to low indoor airflow. Try increasing the blower speed or reducing any restrictions in the airflow. Replacing the air filter can also help.
  • S
    Susan MillsAug 21, 2025
    How to troubleshoot a Rheem RA1336AJ1NA that will not run?
    • C
      cchapmanAug 21, 2025
      If your Rheem Air Conditioner unit won't run, several factors could be the cause. It could be due to a power outage or loose electrical connection, so check the voltage at the line voltage connections. The thermostat might be out of calibration, so try resetting it. A blown fuse or tripped breaker can also prevent the unit from running, so replace the fuses or reset the breaker. Other potential issues include a defective transformer (check the wiring and replace if necessary), an open high-pressure control (reset it), an open low-pressure control, a defective control board (check diagnostic codes), or miswiring of communications (check communication wiring).
  • M
    Michael RamirezAug 23, 2025
    Why is my Rheem RA1336AJ1NA Air Conditioner not cooling properly?
    • S
      Susan CummingsAug 23, 2025
      If your Rheem Air Conditioner isn't cooling enough, several factors could be responsible. The unit might be improperly sized, so recalculate the load. There could be improper indoor airflow; it should be about 400 CFM per ton. The refrigerant charge might be incorrect, so charge it according to the procedure on the unit's service panel. Air, noncondensibles, or moisture in the system can also cause this, in which case you should recover the refrigerant, evacuate, and recharge, adding a filter drier. Finally, a bad ID TXV could be the culprit, requiring replacement.
  • M
    Mary HumphreyAug 26, 2025
    What to do if the Rheem RA1336AJ1NA outdoor fan runs but the compressor doesn't?
    • E
      Elizabeth AndrewsAug 27, 2025
      If the outdoor fan of your Rheem Air Conditioner is running but the compressor isn't, the issue could stem from a defective run or start capacitor, which would need replacement. Alternatively, the contactor might be defective and also require replacement. Check for correct voltage at the compressor and tighten all connections to address any loose connections. If the compressor is stuck, grounded, or has an open motor winding or internal overload, wait at least 3 hours for the overload to reset; if it remains open, replace the compressor. A low-voltage condition could also be the cause, and adding start kit components might resolve the issue.
  • B
    Brittany ByrdAug 28, 2025
    Why does my Rheem RA1336AJ1NA Air Conditioner compressor short cycle?
    • J
      jacksonbradAug 28, 2025
      If the compressor in your Rheem Air Conditioner is short cycling, it could be due to incorrect voltage. Ensure the voltage at the compressor terminals is within ± 10% of the nameplate marking when the unit is operating. Another cause could be a defective overload protector, which would need to be replaced. Also, refrigerant undercharge can cause short cycling, so add refrigerant as needed.
  • T
    thomasmarioAug 30, 2025
    What causes high head pressure with normal vapor pressure in a Rheem RA1336AJ1NA Air Conditioner?
    • J
      Jennifer GarciaAug 30, 2025
      If your Rheem Air Conditioner shows high head pressure with high or normal vapor pressure in cooling mode, the outdoor coil might be dirty, requiring cleaning. Alternatively, the system could be overcharged with refrigerant, necessitating a correction of the system charge. Another possibility is that the outdoor fan isn't running, which means it needs repair or replacement. Lastly, air or noncondensibles in the system can cause this issue, requiring refrigerant recovery, evacuation, and recharge.
  • P
    Paul LunaSep 2, 2025
    Why is the indoor coil of my Rheem RA1336AJ1NA Air Conditioner iced, with low vapor pressure?
    • B
      Bradley SmithSep 2, 2025
      If you notice low vapor pressure, a cool compressor, and an iced indoor coil in your Rheem Air Conditioner, it could be due to low indoor airflow. Try increasing the blower speed or reducing restrictions, and replace the air filter. If you're operating the unit below 65°F outdoors, consider adding a Low Ambient Kit. Moisture in the system can also cause this issue, so recover the refrigerant, evacuate, recharge, and add a filter drier. Finally, a closed ID circuit could be the problem, requiring repair or replacement of the ID coil.
  • S
    sglennSep 5, 2025
    What causes fluctuating head and vapor pressures in a Rheem RA1336AJ1NA?
    • S
      sfarmerSep 5, 2025
      If your Rheem Air Conditioner is experiencing fluctuating head and vapor pressures, it could be due to TXV hunting. Check the TXV bulb clamp and air distribution on the coil; consider replacing the TXV. Another potential cause is air or noncondensibles in the system, which requires recovering the refrigerant, evacuating, and recharging.
  • J
    john09Sep 7, 2025
    What does it mean when my Rheem RA1336AJ1NA has high head and low vapor pressures?
    • M
      Matthew CohenSep 7, 2025
      If your Rheem Air Conditioner has high head pressure but low vapor pressures, there might be a restriction in the liquid line, expansion device, or filter drier. Remove or replace the defective component. Another cause could be a bad TXV, which would need to be replaced.
  • E
    Emily FordSep 10, 2025
    What could cause high vapor pressure in my Rheem RA1336AJ1NA Air Conditioner?
    • D
      Dawn HendersonSep 10, 2025
      If your Rheem Air Conditioner is showing high vapor pressure, it could be due to an excessive load, so recheck the load calculation. Alternatively, the compressor might be defective and need replacement.

Summary

Important Safety Information

AWARNINGS

Critical safety warnings for qualified personnel regarding installation, adjustment, operation, and maintenance.

ACAUTIONS

Precautions for handling R-410A systems, matching components, and installation considerations.

Specifications

Proper Installation

Emphasizes the importance of correct sizing and installation for optimal performance and efficiency.

Installation

Choosing a Location

Guidance on selecting an optimal outdoor unit location for longevity and ease of servicing.

Unit Mounting

Instructions for safely securing elevated units to prevent tipping and potential injury.

Interconnecting Tubing

Refrigerant Level Adjustment

Procedures for calculating and adjusting refrigerant charge based on line set length.

Leak Testing

Procedures for leak testing refrigerant lines using dry nitrogen and soap bubbles.

Wiring

Control Wiring

Details on low-voltage wiring for thermostats and system control circuits.

Power Wiring

Requirements for connecting electrical power supply, including voltage ranges.

Grounding

Critical instructions for permanently grounding the unit to prevent electrical shock.

Start-Up

Checking Airflow

Guidance on verifying and adjusting system airflow for optimal performance.

Evacuation Procedure

Essential steps for evacuating air and moisture from the system to ensure efficiency.

Checking Refrigerant Charge

Procedures for checking and adjusting system refrigerant charge.

Charging Units With R-410 A Refrigerant

Specific guidelines and precautions for charging R-410A systems.

Final Charge by Subcooling

Method for fine-tuning the refrigerant charge using subcooling measurements.

Components and Controls

Diagnostics

Electrical Checks Flowchart

A flowchart to diagnose and troubleshoot electrical issues within the unit.

Cooling Mechanical Checks Flowchart

A flowchart for diagnosing and troubleshooting mechanical problems in cooling mode.

General Troubleshooting Chart

A comprehensive chart listing symptoms, possible causes, and remedies for common issues.

Wiring Diagrams

Rheem RA1336AJ1NA Specifications

General IconGeneral
ModelRA1336AJ1NA
TypeAir Conditioner
Cooling Capacity36, 000 BTU
Tonnage3 Ton
RefrigerantR-410A
Voltage208/230
Phase1
Compressor TypeScroll
StagesSingle Stage
Voltage (V/Ph/Hz)208/230V/1/60Hz
Sound Level (dBA)76

Related product manuals