EasyManua.ls Logo

Rheem RARL-JEZ - Refrigerant Line Sizing; Liquid Line Sizing Charts; Suction Line Sizing and Capacity Multipliers

Rheem RARL-JEZ
36 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Air
Refrigerant Line Size Information
RARL- JEZ Series
Suction Line Run
Feet [m]
25'
[7.62]
50'
[15.24]
100'
[30.48]
150'
[45.72]
Optional
Standard
Optional
Optional
Standard
Optional
Optional
Standard
Optional
Optional
Standard
Optional
5
/8"[15.88 mm] O.D. Std.*
3
/4" [19.05 mm]O.D. Opt.
1.00
1.00
0.99
1.00
0.97
0.98
0.95
0.97
Suction Line Length/Size and Capacity Multiplier
2-Stage R-410A
System Capacity Model
2 Ton 3 Ton
5
/8"[15.88 mm] O.D. Opt.
3
/4" [19.05 mm]O.D. Std.*
.99
1.00
N/A
0.98
0.99
N/A
0.95
0.97
N/A
0.91
0.95
N/A
4 Ton
3
/4" [19.05 mm]O.D. Opt.
7
/8" [22.23 mm]O.D. Std.*
1.00
1.00
N/A
0.98
0.99
N/A
0.95
0.97
N/A
0.93
0.95
N/A
5 Ton
.99
1.00
N/A
0.98
0.99
N/A
0.94
0.97
N/A
0.91
0.95
N/A
Suction Line Connection Size 3/4" [19.05] I.D. 7/8" [22.23] I.D.
NOTES: N/A = Application not recommended.
*Standard line size
NOTES: Line size not recommended due to inadequate oil return.
*Standard line size
[ ] Designates Metric Conversions
Condensing Unit Refrigerant Line Size Information
31