11.3.
Remote controller custom code setting
Selecting the Remote Controller Custom Code
Use the following steps to select the custom code of the remote controller. (Note that the
air conditioner cannot receive a signal if the air conditioner has not been set for the match-
ing custom code.)
1 Press the “MODE” button for at least ve seconds
to display the current custom code (initially set
to A).
2 Press the “SET TEMP.” (
) ( ) button to
change the custom code between
ABCD
.
Match the code on the display to the air condi-
tioner custom code.
3 Press the “MODE” button again. The custom code will be changed.
If no buttons are pressed within 30 seconds after the custom code
is displayed, the display returns to the original display. In this case,
start again from step 1.
Depending on the remote controller, the remote controller custom
code may return to custom code A when the batteries are replaced.
In this case, if you use a code other than A, reset the code after
replacing the batteries.
If you do not know the air conditioner custom code setting, try each
code (ABCD) until you nd the code which operates the air
conditioner.
12. TEST RUN
Check items
(1) Is operation of each button on the remote control unit normal?
(2) Does each lamp light normally?
(3) Do air ow direction louvers operate normally?
(4) Is the drain normal?
(5) Do not have an abnormal noise and vibration during operation?
Do not operate the air conditioner in test run for a long time.
[Operation method]
Depending on your installation, choose from the following:
By the wireless remote controller
To start test run, press the “START/STOP” button and the “TEST RUN” button on the
remote controller.
To end test run, press the remote controller “START/STOP” button.
By the indoor unit
To start test run, press the “MANUAL AUTO” button of the indoor unit for more than
10 seconds (forced cooling).
To end test run, press the “MANUAL AUTO” button for more than 3 seconds or press
the remote controller “START/STOP” button.
By the wired remote controller
For the operation method, refer to the installation manual and the operating manual of
the wired remote controller.
The Operation indicator lamp and Timer indicator lamp will simultaneously ash during the
test run mode.
Heating test run will begin in a few minutes when HEAT is selected by the remote
controller [reverse cycle model only].
13. CUSTOMER GUIDANCE
Explain the following to the customer in accordance with the operating manual:
(1) Starting and stopping method, operation switching, temperature adjustment, timer, air
ow switching, and other remote control unit operations.
(2) Air lter removal and cleaning, and how to use the air louvers.
(3) Give the operating manual to the customer.
14. ERROR CODES
If you use a wireless remote controller, the lamp on the photo detector unit will output er-
ror codes by way of blinking patterns. If you use a wired remote controller, error codes will
appear on the remote controller display. See the lamp blinking patterns and error codes in
the table. An error display is displayed only during operation.
Error display
Wired
remote
controller
Error code
Description
OPERATION
lamp (green)
TIMER
lamp
(orange)
ECONOMY
lamp
(green)
(1)
(1)
Serial communication error
(1)
(2)
Wired remote controller
communication error
(1)
(5)
Check run unfinished
(1)
(6)
Peripheral unit transmission PCB
connection error
(1)
(8)
External communication error
(2)
(1)
Unit number or Refrigerant circuit
address setting error
[Simultaneous Multi]
(2)
(2)
Indoor unit capacity error
(2)
(3)
Combination error
(2)
(4)
• Connection unit number
error (indoor secondary unit)
[Simultaneous Multi]
• Connection unit number error
(indoor unit or branch unit)
[Flexible Multi]
(2)
(6)
Indoor unit address setting error
(2)
(7)
Primary unit, secondary unit setup
error [Simultaneous Multi]
(2)
(9)
Connection unit number error in
wired remote controller system
(3)
(1)
Power supply interruption error
(3)
(2)
Indoor unit PCB model
information error
(3)
(5)
Manual auto switch error
(3)
(10)
Indoor unit communication circuit
(wired remote controller) error
(4)
(1)
Room temp. sensor error
(4)
(2)
Indoor unit Heat Ex. Middle temp.
sensor error
(4)
(4)
Human sensor error
(5)
(1)
Indoor unit fan motor error
(5)
(3)
Drain pump error
(5)
(7)
Damper error
(5)
(8)
Intake grille error
(5)
(15)
Indoor unit error
(6)
(1)
Outdoor unit reverse/missing
phase and wiring error
(6)
(2)
Outdoor unit main PCB
model information error or
communication error
(6)
(3)
Inverter error
(6)
(4)
Active filter error, PFC circuit error
(6)
(5)
Trip terminal L error
(6)
(10)
Display PCB microcomputers
communication error
(7)
(1)
Discharge temp. sensor error
(7)
(2)
Compressor temp. sensor error
(7)
(3)
Outdoor unit Heat Ex. liquid temp.
sensor error