(4) Use cable clamper and screw to fasten the cable of wired remote controller.
cable clamper
screw
screw
cable clamper
cable of wired
remote controller
original wire of control unit
conduit holder
(5) Fix the cable clamp with the screw and bind the wire of external kit with the cable tie.
external connect wire
conduit holder
screw
cable clamp
original wire of
control box
external connect wire
cable clamp
screw
cable tie
10.5.
Front panel, control box cover and display case installation
Install front panel, control box cover and display case by the reverse procedures as stated
in 10.4. Front panel, control box cover and display case removal.
11. FUNCTION SETTING
Perform the Function setting according to the installation conditions using the remote controller.
CAUTION
Con rm whether the wiring work for outdoor unit has been nished.
Con rm that the cover for the electrical enclosure on the outdoor unit is in place.
This procedure changes to the function settings used to control the indoor unit according
to the installation conditions. Incorrect settings can cause the indoor unit to malfunction.
After the power is turned on, perform the Function setting according to the installation
conditions using the remote controller.
The settings may be selected between the following two:
Function Number and Setting Value.
Settings will not be changed if invalid numbers or setting values are selected.
Match the custom code of the indoor unit and the custom code of the remote controller.
(Refer to “Selecting the remote controller custom code”)
Entering the Function Setting Mode
While pressing the “FAN” button and “Set TEMP.” ( ) button simultaneously, press the
“RESET” button to enter the function setting mode.
STEP 1
Setting the Remote Controller Custom Code
Use the following steps to select the custom
code of the remote controller. (Note that the air
conditioner cannot receive a signal if the air con-
ditioner has not been set for the matching cus-
tom code.) The custom code that is set through
this process are applicable only to the signal in
the Function setting. For details on how to set
the custom code through the normal process,
refer to “Selecting the Remote Controller Cus-
tom Code”.
(1) Press the “SET TEMP.” (
) ( ) button to change the custom code between
ABCD
Match the code on the display to the air conditioner custom code.
(initially set to A) (If the custom code does not need to be selected, press the “MODE”
button and proceed to STEP 2.)
(2) Press the “MODE” button to accept the custom code, and proceed to STEP 2
STEP 2
Selecting the Function Number and Setting Value
(1) Press the “SET TEMP.” ( ) ( ) buttons to
select the function number.
(Press the “MODE” button to switch between
the left and right digits.)
(2) Press the “FAN” button to proceed to setting the
value.
(Press the “FAN” button again to return to the
function number selection.)
(3) Press the “SET TEMP.” (
) ( ) buttons to
select the setting value.
(Press the “MODE” button to switch between
the left and right digits.)
(4)
Press the “SLEEP” button, then after you hear
the beep emitted from the indoor unit, press the
“START/STOP” button to con rm the settings.
(5) Press the “RESET” button to cancel the function setting mode.
(6) After completing the Function setting, be sure to disconnect the power and reconnect
it again.
CAUTION
After disconnecting the power, wait 30 seconds or more before reconnecting it.
The Function Setting does not become active unless the power is disconnected then
reconneccted again.
Note :
*1: A small “A” is displayed on the right of the function number or setting value during the
Function setting.
11.1.
Function details
Filter Sign
Select appropriate intervals for displaying the lter sign on the indoor unit according to the
estimated amount of dust in the air of the room.
If the indication is not required, select “No indication” (03).
(... Factory setting)
Function Number
Setting
Value
Setting Description
11
00 Standard (400 hours)
01 Long interval (1000 hours)
02 Short interval (200 hours)
03 No indication
*1
*1
*1
Function
number
Setting
value
9318739244_IM.indb 99318739244_IM.indb 9 2016/11/29 10:40:182016/11/29 下午 10:40:18