ELECTRICAL DATA – RKNL SERIES
B073CL B073CM B073DL B073DM B073YL B073YM B090CL B090CM B090CN B090DL B090DM
Unit Information
Unit Operating
Voltage Range
187-253 187-253 414-506 414-506 518-632 518-632 187-253 187-253 187-253 414-506 414-506
Volts
208/230 208/230 460 460 575 575 208/230 208/230 208/230 460 460
Minimum Circuit Ampacity
35/35 35/35 16 16 13 13 43/43 43/43 48/48 21 21
Minimum Overcurrent
Protection Device Size
40/40 40/40 20 20 15 15 45/45 45/45 50/50 25 25
Maximum Overcurrent
Protection Device Size
50/50 50/50 20 20 15 15 50/50 50/50 60/60 25 25
Compressor Motor
No.
1 1 111122222
Volts
200/240 200/240 480 480 600 600 200/240 200/240 200/240 480 480
Phase
3 3 333333333
RPM
3450 3450 3450 3450 3450 3450 3450 3450 3450 3450 3450
HP, Compressor 1
6 6 5 6 5 6 3 1/4 3 1/4 3 1/4 3 1/4 3 1/4
Amps (RLA), Comp. 1
19.6/19.6 19.6/19.6 8.2 8.2 6.6 6.6 13.1/13.1 13.1/13.1 13.1/13.1 6.1 6.1
Amps (LRA), Comp. 1
136/136 136/136 66.1 66.1 55.3 55.3 83.1/83.1 83.1/83.1 83.1/83.1 41 41
Condenser Motor
No.
2 2 222222222
Volts
208/230 208/230 460 460 575 575 208/230 208/230 208/230 460 460
Phase
1 1 111111111
HP
1/3 1/3 1/3 1/3 1/3 1/3 1/3 1/3 1/3 1/3 1/3
Amps (FLA, each)
2.4/2.4 2.4/2.4 1.4 1.4 1 1 2.4/2.4 2.4/2.4 2.4/2.4 1.4 1.4
Amps (LRA, each)
4.7/4.7 4.7/4.7 2.4 2.4 1.5 1.5 4.7/4.7 4.7/4.7 4.7/4.7 2.4 2.4
Evaporator Fan
No.
1 1 111111111
Volts
208/230 208/230 460 460 575 575 208/230 208/230 208/230 460 460
Phase
3 3 333333333
HP
1 1/21 1/21 1/21 1/21 1/21 1/222322
Amps (FLA, each)
5.6/5.6 5.6/5.6 2.8 2.8 1.9 1.9 8/8 8/8 13/13 4 4
Amps (LRA, each)
28.8/28.8 28.8/28.8 14.4 14.4 14 14 56/56 56/56 74.5/74.5 28 28