- (01-07) -
WALL MOUNTED TYPE
RIWH09-12AVFJ
WALL MOUNTED TYPE
RIWH09-12AVFJ
4-2. HEATING CAPACITY
MODEL : RIWH09AVFJ
AFR 441
Indoor temperature
°FDB 60 65 70 75
Outdoor temperature
°FDB °FWB TC IP TC IP TC IP TC IP
5 3 7.18 0.68 7. 01 0.69 6.84 0.71 6.66 0.72
14 12 8.13 0.73 7.9 4 0.75 7.74 0.76 7. 5 5 0.78
23 19 9.10 0.76 8.88 0.78 8.66 0.79 8.45 0.81
32 28 10.48 0.81 10.23 0.83 9.98 0.84 9.73 0.86
41 37 11.91 0.86 11.63 0.88 11.34 0.90 11.0 6 0.92
47 43 12.60 0.85 12.30 0.87 12.00 0.89 11.70 0.91
50 47 12.26 0.73 11.97 0.75 11.68 0.76 11.39 0.78
59 50 12.47 0.72 12.18 0.74 11.88 0.75 11. 58 0.77
68 59 12.82 0.67 12.51 0.68 12.21 0.70 11.90 0.71
75 65 13.32 0.67 13.00 0.68 12.68 0.69 12.36 0.71
AFR
: Air ow rate (CFM)
TC : Total capacity (kBTU)
IP : Input Power (kW)
AFR 750
Indoor temperature
°CDB 15.6 18.3 21.1 23.9
Outdoor temperature
°CDB °CWB TC IP TC IP TC IP TC IP
-15 2.10 2.10 0.68 2.05 0.69 2.00 0.71 1.95 0.72
-10 2.38 2.38 0.73 2.33 0.75 2.27 0.76 2.21 0.78
-5 2.67 2.67 0.76 2.60 0.78 2.54 0.79 2.48 0.81
0 3.07 3.07 0.81 3.00 0.83 2.93 0.84 2.85 0.86
5 3.49 3.49 0.86 3.41 0.88 3.32 0.90 3.24 0.92
7 3.69 3.69 0.85 3.61 0.87 3.52 0.89 3.43 0.91
10 3.59 3.59 0.73 3.51 0.75 3.42 0.76 3.34 0.78
15 3.66 3.66 0.72 3.57 0.74 3.48 0.75 3.40 0.77
20 15 3.76 0.67 3.67 0.68 3.58 0.70 3.49 0.71
24 18 3.90 0.67 3.81 0.68 3.72 0.69 3.62 0.71
AFR : Air ow rate (m
3
/h)
TC : Total capacity (kW)
IP : Input Power (kW)
MODEL : RIWH12AVFJ
AFR 441
Indoor temperature
°FDB 60 65 70 75
Outdoor temperature
°FDB °FWB TC IP TC IP TC IP TC IP
5 3 10.71 1.09 10.46 1.12 10.20 1.14 9.95 1.16
14 12 12.04 1.13 11.76 1.15 11. 47 1.18 11.18 1.20
23 19 13.35 1.18 13.03 1.20 12.71 1.23 12.40 1.25
32 28 15 .17 1.26 14.80 1.29 14.44 1.31 14.08 1.34
41 37 16 .13 1.23 15.75 1.25 15.36 1.28 14.98 1.30
47 43 16.80 1.23 16.40 1.25 16.00 1.28 15.60 1.31
50 47 17. 20 1.23 16.79 1.25 16.38 1.28 15.97 1.30
59 50 16.87 1.15 16.47 1.17 16.07 1.20 15.67 1.22
68 59 15.63 0.91 15.25 0.92 14.88 0.94 14.51 0.96
75 65 15.94 0.89 15.56 0.91 15.18 0.93 14.80 0.95
AFR
: Air ow rate (CFM)
TC : Total capacity (kBTU)
IP : Input Power (kW)
AFR 750
Indoor temperature
°CDB 15.6 18.3 21.1 23.9
Outdoor temperature
°CDB °CWB TC IP TC IP TC IP TC IP
-15 -16 3.14 1.09 3.07 1.12 2.99 1.14 2.92 1.16
-10 -11 3.53 1.13 3.45 1.15 3.36 1.18 3.28 1.20
-5 -7 3.91 1.18 3.82 1.20 3.73 1.23 3.63 1.25
0 -2 4.44 1.26 4.34 1.29 4.23 1.31 4.13 1.34
5 3 4.73 1.23 4.62 1.25 4.50 1.28 4.39 1.30
7 6 4.92 1.23 4.81 1.25 4.69 1.28 4.57 1.31
10 8 5.04 1.23 4.92 1.25 4.80 1.28 4.68 1.30
15 10 4.94 1.15 4.83 1.17 4.71 1.20 4.59 1.22
20 15 4.58 0.91 4.47 0.92 4.36 0.94 4.25 0.96
24 18 4.67 0.89 4.56 0.91 4.45 0.93 4.34 0.95
AFR : Air ow rate (m
3
/h)
TC : Total capacity (kW)
IP : Input Power (kW)