- (02 - 03) -
OUTDOOR UNIT
ROSH09-12AFWJ
OUTDOOR UNIT
ROSH09-12AFWJ
MODEL : ROSH12AFWJ
31-1/8 (790)
13-7/8 (352)
13/16 (20)
21-1/4 (540)
13-16 (20)
12-1/2 (318)
3/8 (9)
2-11/16 (68) 11/16 (18)3/8 (10) 11-7/16 (290)
21-1/4 (540)
8-1/4 (209)
4-5/16 (110)
6-7/8 (175)
Unit : in.(mm)
INSTALLATION PLACE
• Height above the oor level should be 2 in. (50 mm) or more.
• To obtain better operation efciency, when the outdoor unit
is installed, be sure to open the front and left side.
24 (600) or more
4 (100) or more
8 (200) or more
4 (100) or more
10 (250) or more
(Service space)
CAUTION
When the outdoor temperature is 32 °F
(0 °C ) or less, do not use the accessory
drain pipe and drain cap. If the drain pipe
and drain cap are used, the drain water in
the pipe may freeze in extremely cold
weather. (Reverse cycle model only)
In areas with heavy snowfall, if the intake
and outlet of outdoor unit is blocked with
snow, it might become difficult to get warm
and it is likely to cause breakdown.
Please construct a canopy and a pedestal or
place the unit on a high stand (local
configured).
Unit : in.(mm)